FCP-031 TDK Corp., FCP-031 Datasheet
FCP-031
Related parts for FCP-031
FCP-031 Summary of contents
Page 1
... FCP-101 9.6 +12 FCP-102 9.6 +15 FCP-B Output1[V Maximum output Part No. power(W) Voltage(V) FCP-031B 2.9 +12 FCP-032B 3 +15 FCP-101B 9.6 +12 FCP-102B 9.6 +15 • The above products are only produced upon receipt of order. Please check a delivery date. • Conformity to RoHS Directive: This means that, in conformity with EU Directive 2002/95/EC, lead, cadmium, mercury, hexavalent chromium, and specific bromine-based flame retardants, PBB and PBDE, have not been used, except for exempted applications. • ...
Page 2
... Although there is no built-in overvoltage protection circuit, the overvoltage prevention method is used for circuit design, thereby preventing overvoltage. • All specifications are subject to change without notice. FCP-031 +12V • 0.12A –12V • 0.12A 2 132[Rating: 100 to 120 66[Rating 60](Single phase) 0.08typ.[25° ...
Page 3
... AC INPUT N 11max. 50±0.7 5 40±0.4 (5) Connect to load output – output 2 0V: Ground common to V and V 1 Connected to earth pattern for input line. Connect to AC.100-120V single phase input line. 55±0.7 2-M3 Tap ±0.7mm: without specified dimensions 2 002-01 / 20051206 / ea152_fcp.fm (3/12) Dimensions in mm ...
Page 4
... FCC class B meet. × × × × 80[H W L](Except input and output terminals) 100max. Can be attached to 1 side. Nonflammable resin — FCP-102 +15V • 0.32A –15V • 0.32A 9.6 +15[V ] –15 13.5 to 16.5[V varies simultaneously 0.32 0.32 0.03 0.03 15.1 — 0.32 0.32 Total effect ±3max.(±1typ.) 002-01 / 20051206 / ea152_fcp.fm (4/12) ...
Page 5
... Voltage adjustment trimmer on opposite. 5 70±0.4 (5) Connect to load output – output 2 0V: Ground common to V and V 1 Connected to earth pattern for input line. Connect to AC.100-120V single phase input line. 55±0.7 2-M3 Tap Dimensions in mm ±0.7mm: without specified dimensions 2 002-01 / 20051206 / ea152_fcp.fm (5/12) ...
Page 6
... Although there is no built-in overvoltage protection circuit, the overvoltage prevention method is used for circuit design, thereby preventing overvoltage. • All specifications are subject to change without notice. FCP-031B +12V • 0.12A –12V • 0.12A 2 132[Rating: 100 to 120 66[Rating 60](Single phase) 0.08typ.[25° ...
Page 7
... AC INPUT 50 1.2±0.2 41±0.5 (5) M3 Tap Connect to load output – output 2 0V: Ground common to V and V 1 Connected to earth pattern for input line. Connect to AC.100-120V single phase input line. Dimensions in mm ±0.7mm: without specified dimensions 2 002-01 / 20051206 / ea152_fcp.fm (7/12) ...
Page 8
... FCC class B meet. × × × × 80[H W L](Except input and output terminals) 100max. Can be attached to 1 side. Nonflammable resin — FCP-102B +15V • 0.32A –15V • 0.32A 9.6 +15[V ] –15 13.5 to 16.5[V varies simultaneously 0.32 0.32 0.03 0.03 15.1 — 0.32 0.32 Total effect ±3max.(±1typ.) 002-01 / 20051206 / ea152_fcp.fm (8/12) ...
Page 9
... AC INPUT 80 1.2±0.2 71±0.5 (5) M3 Tap Connect to load output – output 2 0V: Ground common to V and V 1 Connected to earth pattern for input line. Connect to AC.100-120V single phase input line. Dimensions in mm ±0.7mm: without specified dimensions 2 002-01 / 20051206 / ea152_fcp.fm (9/12) ...
Page 10
... Edc: 500V, 100M min. [Normal temperature, normal humidity] Input Output rectifying smoothing and circuit smoothing circuit Over- Output rectifying Power current and switching detection circuit smoothing circuit circuit Drive circuit Control Control circuit circuit 50 60 (10/12) V Series 2 regulator DC output 002-01 / 20051206 / ea152_fcp.fm ...
Page 11
... AC input H: 10ms/DIV • Three numeric values in the above data indicate output voltages exceed 90% of the rated output voltage at the input voltage AC.85/100/132V. • All specifications are subject to change without notice. OUTPUT CHARACTERISTICS(25°C) 3W TYPE FCP-031 14 12 AC.132V 10 AC.85V 8 AC.100V 6 ...
Page 12
... Unit: Thousand In chain In loose ∗ 60573-2 60711-2 20 ∗ 60573-1 60711-1 170214-2 170203-2 9 ∗ 60621-1 61020-1 20 170037-1 170038-1 170037-2 170038-2 9 60487-2 — ® ® Connector and Fastine Faston Connector." 002-01 / 20051206 / ea152_fcp.fm (12/12) in the table Unit: mm Quantity/ reel 10,000 10,000 Unit: mm ...