ATF-1500-12-YE Martek Power, ATF-1500-12-YE Datasheet - Page 2

no-image

ATF-1500-12-YE

Manufacturer Part Number
ATF-1500-12-YE
Description
12v Output, 1500 Watts Ac Front End
Manufacturer
Martek Power
Datasheet
www.martekpower.com
1111 Knox Street
Maximum Output Power
Maximum Output Voltage
Maximum Output Current
Minimum Load
Overshoot
Transient Response
Transient Response max. deviation
Turn-On Delay with PS_ON signal
OverCurrent Protection
OverVoltage Protection
Short Circuit Protection
OverTemperature
Loop Stability
Regulation
Ripple & Noise @ 20 MHz BW
O O
U U T T P P U U T T
C C
H H A A R R A A C C T T E E R R I I S S T T I I C C S S
Torrance
( ( A A T T F F - - 1 1 5 5 0 0 0 0 - - 1 1 2 2 - - Y Y ) )
131.25
CA 90502
Min
0
A A N N D D
Typ
P P
±5
R R O O T T E E C C T T I I O O N N
USA
Max
137.5
1500
125
12
0
4
D D
E E F F I I N N I I T T I I O O N N
Tel: +1 310 542 8561
Watts
VDC
A
A; minimum loading required to maintain regulation.
%
ms; maximum recovery time to within 1% of initial set
point due to a 50% load change, 1A/μs at 12V output
%; 12V output
sec; time required for initial output voltage stabilization
after application of AC intput
A; latching style overcurrent protection w/ adpative delay
V; latching style overvoltage protection
Latching Mode.
12V output will shut down in the event of an over
temperature condition or blocked fan rotor.
Power supply will recover when over temperature
condition is removed.
degree; phase margin @ 0 gain crossover frequency
dB, gain margin @ 0-phase crossover frequency
% (Due to droop)
mV
Units / Comments
sales@martekpower.com
>> 2

Related parts for ATF-1500-12-YE