FCM400 XP Power Limited, FCM400 Datasheet - Page 2

no-image

FCM400

Manufacturer Part Number
FCM400
Description
Power Module 400 Watts Fcm400 Series Dc-dc Converter
Manufacturer
XP Power Limited
Datasheet
Models and Ratings
Notes
1. Peak Output Power - The peak duration is 500 ms maximum, average power must not exceed 400 W.
2. For 500 W continuous output power, contact sales.
Mechanical Details
600
320
540
400
360
300
Input Terminal Block
Input Voltage & Temperature Derating
80
(CON 4)
85
M3 mounting holes (in 2 positions, each side). Max penetration
Input Voltage (VAC)
by screw to be 0.14 in (3.5 mm) from outside face of chassis
90
(26.2)
1.03
2.10 (53.4)
penetration by screw to be 0.10 in (2.5 mm)
Peak Power Availability
M3 Mounting holes (in 4 positions). Max
from bottom face of chassis
6.00 (152.4)
3.94 (100.0)
264
3.35 (85.0)
275
(13.3)
Output terminals
allow connection
from either top or
side (CON 3)
0.52
Signals connection
P/F Emitter
+Ve ROF
+5Ve
600
200
500
400
300
100
0
-10
P/F Collector
-Ve ROF
-5Ve
0
10
Peak Power Availability
Ambient Temperature (°C)
Signal
Connections
(CON 1)
Voltage adj.
Output
terminals
M4 screws in
2 positions.
Torque to
8 lbs-in
(90 cNm) max.
40
50
FCM400
Notes
60
70

Related parts for FCM400