IR3505M International Rectifier Corp., IR3505M Datasheet - Page 16
IR3505M
Manufacturer Part Number
IR3505M
Description
Xphase3 Phase Ic
Manufacturer
International Rectifier Corp.
Datasheet
1.IR3505M.pdf
(19 pages)
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
PCB Metal and Component Placement
• Lead land width should be equal to nominal part lead width. The minimum lead to lead spacing should
• Lead land length should be equal to maximum part lead length + 0.3 mm outboard extension + 0.05mm
• Center pad land length and width should be equal to maximum part pad length and width. However, the
• Four 0.3mm diameter vias shall be placed in the pad land spaced at 0.85mm, and connected to ground
be ≥ 0.2mm to minimize shorting.
inboard extension. The outboard extension ensures a large and inspectable toe fillet, and the inboard
extension will accommodate any part misalignment and ensure a fillet.
minimum metal to metal spacing should be ≥ 0.17mm for 2 oz. Copper (≥ 0.1mm for 1 oz. Copper and ≥
0.23mm for 3 oz. Copper)
to minimize the noise effect on the IC, and to transfer heat to the PCB
Page 16 of 19
Sept 26
th
IR3505
, 2007