NVA3-453TTH-N3 TDK Corp., NVA3-453TTH-N3 Datasheet

no-image

NVA3-453TTH-N3

Manufacturer Part Number
NVA3-453TTH-N3
Description
300 Watts Flexible Power Solution
Manufacturer
TDK Corp.
Datasheet
1. 1, 2, 3, 2H & 3H channel 2 only available with 5V channel 1.
2. Maximum combined output current from Ch1 & Ch2 = 40A
3. Follow letters in red by ‘P’ for positive output channel 4.
Input Voltage
Input Harmonics
Input Fuse
Earth Leakage Current
Channel 1
5
T
G
INPUT
AVAILABLE OUTPUTS
• High Efficiency
• Low Profile
• High Power Density
5V / 10A channel 2 only available with 12 or 15V channel 1
5V / 8A channel 2 only available with 24V channel 1
NV-300
300 Watts
Flexible Power Solution
Features and Benefits
Features
5V / 40A
12V / 25A
24V / 12.5A
2
Adjustment
Range
5 - 5.5V
12 - 13V
24 - 28V
90 - 264Vac / 120 - 350Vdc
(Below 100Vac input, derate by 3W per Volt)
EN61000-3-2 compliant
6.3A, Fast acting (not user accessible)
123µA max at 120Vac (60Hz), 257µA max at 240Vac (60Hz)
Worst case leakage current is less than 300µA at 264Vac, 63Hz (normal condition, 500µA Single Fault Condition)
5
7
Other output options are available, please contact factory with your requirements.
Channel 2
1
2
3
2H
3H
0
5
5H
0
5
5H
T
F
0
1.8V / 15A
2.7V / 15A
3.3V / 15A
2.7V / 24A
3.3V / 24A
Omit
5V / 10A
5V / 16A
Omit
5V / 8A
5V / 12.5A
12V / 10A
15V / 10A
Omit
1
NV-Power Series (NV-300)
4. 60W max output power
5. Max voltage at the output (includes remote sense)
6. 96W max output power
7. 24 - 24.5V if 5V channel 2 fitted
Adjustment
Range
0.9 - 2.5V
2.5 - 3.8V
2.5 - 3.8V
2.5 - 3.8V
2.5 - 3.8V
3.3 - 5.5V
3.3 - 5.5V
5 - 5.5V
5 - 5.5V
12 - 15.5V
12 - 15.5V
24 - 26V if 24V channel 3 fitted
Benefits
5
• Minimises heat in system
• Fits 1U applications
• Less Space
Input Frequency
Inrush Current
Power Factor
Channel 3
T
TH
F
FH
G
0
12V / 5A
12V / 8A
15V / 4A
15V /6.4A
24V / 2.5A
Omit
• High Efficiency
• High Power Density (8.3W/in³)
• Up to 5 outputs
• No minimum load
• Fits 1U applications
• Medical Approval
• 3 Year Warranty
• Temperature controlled Fan Option
Key Market Segments & Applications
Instrumentation
Medical
Automation
Security
Network Servers and Routers
4
6
4
6
Adjustment
Range
12 - 15V
12 - 15V
12 - 15V
12 - 15V
18 - 24V
45 - 63Hz
(440Hz with reduced PFC - consult factory)
15A (typical) at 20°C and 264Vac, (cold start)
0.97 typical
8. 1.5A max if fitted with ‘-F’ option.
Channel 4
3H
5H
TH
FH
0H
0
-3.3V / 2A
-5V / 2A
-12V / 2A
-15V / 2A
Fan supply only
Omit
Broadcast
ATE
Industrial Computing
Lifesciences/Laboratory
3
8
8
8
8
Adjustment
Range
Fixed
Fixed
Fixed
Fixed
1

Related parts for NVA3-453TTH-N3

NVA3-453TTH-N3 Summary of contents

Page 1

NV-300 300 Watts Flexible Power Solution Features and Benefits Features • High Efficiency • Low Profile • High Power Density INPUT 90 - 264Vac / 120 - 350Vdc Input Voltage (Below 100Vac input, derate by 3W per Volt) Input Harmonics ...

Page 2

... Needs 0H, 3H, 5H type channel 4. The fan speed is temperature de- pendent, ensuring optimum cooling and lowest audible noise. QUICK SELECTOR - preferred configurations Model CH1 NVA3-453TTH 5V / 40A NVA3-453TTH- 40A NVA3-350TTH 5V / 40A NVA3-350TTH- 40A NVA3-453FFH 5V / 40A NVA3-453FFH- 40A ...

Page 3

GLOBAL SIGNALS (-N3 and -N4 Option Models) ATX Remote on/off TTL logic level high or open circuit will inhibit all outputs (except Standby) ATX Power Good Logic high indicates ac supply is good and output 1 is within regulation. Common ...

Page 4

OUTLINE & CONNECTION DRAWINGS ...

Page 5

OUTLINE & CONNECTION DRAWINGS NV300 OUTLINES & CONNECTIONS NV300 OUTLINES & CONNECTIONS NV300 OUTLINES & CONNECTIONS NV300 OUTLINES & CONNECTIONS CASING OPTIONS. ISSUE 1 25.09.06 (PROVISIONAL) CASING OPTIONS. ISSUE 1 25.09.06 (PROVISIONAL) CASING OPTIONS. ISSUE 1 25.09.06 (PROVISIONAL) CASING OPTIONS. ...

Page 6

Document number 69687 - Rev 5.0 - Jan 09 6 NV-Power Series (NV-300) ...

Related keywords