V110B Vicor Corporation, V110B Datasheet - Page 2

no-image

V110B

Manufacturer Part Number
V110B
Description
Dc-dc Converter Module
Manufacturer
Vicor Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
V110B3V3T100BG
Quantity:
387
Part Number:
V110B5C150BG
Manufacturer:
VICOR
Quantity:
20 000
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature,
unless otherwise specified. All temperatures refer to the operating temperature at the center of the baseplate.
Operating input voltage
Input surge withstand
Undervoltage turn-on
Undervoltage turn-off
Overvoltage turn-off/on
Output voltage setpoint
Line regulation
Temperature regulation
Power sharing accuracy
Programming range
Baseplate to sink; flat, greased surface
Baseplate to sink; thermal pad (P/N 20265)
Baseplate to ambient
Baseplate to ambient; 1000 LFM
Thermal capacity
3.3 V
5 V
8 V
12 V
15 V
24 V
28 V
36 V
48 V
For important information relative to applications where the converter modules are subject to continuous dynamic loading, contact Vicor applications
engineering at 800-927-9474.
Set your site on VICOR at www.vicorpower.com
155.5
66
54
10
±0.002
161.7
±0.02
110
± 2
64
56
–0.5 to 10.9
–0.5 to 16.1
–0.5 to 20.0
–0.5 to 31.7
–0.5 to 36.9
–0.5 to 47.4
–0.5 to 62.9
–0.5 to 4.7
–0.5 to 7.0
±0.005
169.4
±0.20
65.4
154
250
110
± 5
±1
110V Mini Family
% Vout nom.
0.16
0.14
8.0
1.9
83
% / °C
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
%
%
%
EN50155
<100 ms
Nominal input; full load; 25°C
Low line to high line; full load
Over operating temperature range
10 to 100% of full load
Of nominal output voltage. For trimming below 90%
of nominal, a minimum load of 10% of maximum
rated power may be required.
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Watt-sec/°C
°C/Watt
°C/Watt
°C/Watt
°C/Watt
Rev. 1.9
Page 2 of 13