ZCS1-120 American Zettler, Inc., ZCS1-120 Datasheet - Page 2

no-image

ZCS1-120

Manufacturer Part Number
ZCS1-120
Description
Water Resistant Solenoid
Manufacturer
American Zettler, Inc.
Datasheet
ZCS1-120
GENERAL DATA
MECHANICAL DATA
APPLICATION NOTES:
1.) Not all number combinations are available. Please contact your Sales Representative for available
part numbers.
2.) Solenoid applied in battery charging circuits should be protected from higher than rated voltage during charging.
The service life may be affected by this condition and the solenoid may or may not operate the circuit as intended.
3.) Circuits should be designed to provide safe operation should the solenoid fail in either the open or closed position.
4.) A back-up wrench must be used to hold the bottom nut stationary during installation.
Dielelectric Strength
Temperature Range
Mechanical Life (no load)
Mounting position (Recommended)
Duty Cycle
Hardward Torque specification
Weight
16
5“
THREAD TYP
2.4 UNF- 2A
4
Dimensions and Mounting
3.253
for Standard Bracket
#10 - 32 UNF -2A
THREAD TYPE
Dimensions and Mounting
500 Volts
-20°F~150°F (-28.9°C~65.6°C) - Intermittent
-20°F~120°F (-28.9°C~48.9°C) - Continuous
250,000 cycles
Plunger vertical with cap down
Continuous; Intermittent: 10sec "on"
maximum and minimum 60sec "off".
60sec "on" max and minimum 6min "off."
44-55 in*lbs (Contact terminal);
12-18 in*lbs (Coil terminal)
170.5 grams
2 - 0.281X0.400
Cap / Plunger
1.375
2.125
2.875
Wiring diagram
10/11/06

Related parts for ZCS1-120