(6) INITIAL VALUE CHANGE FUNCTIONS
Continue to next page
No.
1
2
3
4
5
Initial value, OSD items, etc. can be changed.
The changed initial value becomes initial value in each preset timing, and is applicable when it is reset
(including All Reset).
• How to transpose to initial value change mode.
• Operation
• How to return to normal mode
Hierarchical type: Connect SET and UP to GND at the same time when OSD function is in “information”
Toggle type
SEL, UP, DOWN, and EXIT
Connect EXIT to GND or turn off Power supply when OSD is closed.
Both LEDON and LEDOFF become “H” when this mode is operating.
Compatible
Brightness
Color Level
Contrast
LCD Data
Form
: Connect SEL to GND while UP is connected to GND when OSD function is in “All Reset”
mode.
mode.
Mode
HSE
Delay
VD
HD
Auto Adjust
Par. Delay
Par. HD
It becomes valid when Toggle menu type is only selected.
The initial value of contrast (RGB synchronous) becomes 100.
The NEC factory value: NO.
The maximum value of brightness of backlight can be changed.
Initial value: 100
The initial value of color level can be changed.
Initial value: 128
The initial value of contrast can be changed.
Initial value: 128
No. of Page 12 PRESET TIMINGS is displayed.
The initial value of the Double Value can be changed.
The value of the CLK delay can be changed. (Initial value can not be
changed.)
The initial value of the up-down position of the display position can be
changed.
The initial value of the left-right position of the display position can be
changed.
Auto adjust
The compensation value of Delay of the auto adjust can be changed.
The compensation value of horizontal position of the auto adjust can be
changed.
Data Sheet EN0444EJ1V0DS00
YES : Sync on Green
The initial value of contrast (RGB synchronous) becomes 128.
NO : No Sync on Green
(When NO is selected by Compatible in Toggle menu type, the initial value
of RGB synchronous only is 100.
As for RGB synchronous, the setup value described in this item becomes
valid as the Initial value regardless of the selections state of Compatible.)
Initial value: 0
Valid range: 0 to 255