IRA-E940 Murata Manufacturing, IRA-E940 Datasheet - Page 14

no-image

IRA-E940

Manufacturer Part Number
IRA-E940
Description
(IRA-Exxx) Pyroelectric Infrared Sensors
Manufacturer
Murata Manufacturing
Datasheet
5
Please read CAUTION and Notice in this catalog for safety. This catalog has only typical specifications. Therefore you are requested
to approve our product specification or to transact the approval sheet for product specification, before your ordering.
! Max. Rating (25˚C)
! Rating (25˚C)
! Timing Chart (IMD-B101-01)
! Reliability Test
12
Max. Supply Voltage
Operating Temp. Range
Storage Temp. Range
Supply Voltage
Current
Consumption
Output Terminal
Output Current
Output Pulse Width
Prohibited Time
Wave Length Range
Detection
Length
Detection Range
Pyroelectric Infrared Sensor Module IMD Series
High Temperature
Low Temperature
Humidity
Heat Cycle
Vibration
Shock
Soldering Heat
Hermetic Sealing
Prohibited Period
Analog Output
Digital Output
Item
Items
Ready Period
Active Period
Without Lens
With IMD-FL01W/G
P
1
60D for 500 hrs.
Y20D for 500 hrs.
60D, 95% RH for 150 hrs.
20 times of following cycle.
Y20D, 30min.eRoom temp., 30minh
gRoom temp., 30min.f60D, 30min.
Apply vibration of amplitude of 1.5mm with 10 to 55Hz band to each of 3
perpendicular directions for 2 hrs.
Apply shock of 30G sinewave by standard shock tester to each of 3
perpendicular directions for 5 times.
Immerse up to 3.0mm from can case in solder bath of 260T5D for 10T1 s.
Conform to MIL-STD-202F chapter 112D, condition D.
Immerse in fluorocarbon bath (FC-40) of 125T5D for 20 s.
(P1)
(P2)
Y10 to W50D (Without condensation)
P
2
Y20 to W60D
119°Z38° (Max.)
50Y120µA
5.5V
2.6Y5.5V
30Y60µA
1.0Y3.0s
5Y14µm
C-MOS
F3.0s
1mA
1m
5m
Test Conditions
! Detection Area (With Fresnel Lens)
! Typical Application (IMD-B102-01)
LOAD
•CdS Input is required to be Vcc 3.9W0.2V/Y0.4V or higer to operate.
•IMD-B101-01 generates analog output at Pin (2).
Horizontal Area
Vertical Area
500
R
L
U1k
3
4
After test completion, leave for three hours in
normal humidity temperature conditions, and
then measure.
1. External appearance:
2. Sensitivity:
3. Current consumption:
No generation of bubbles.
No significant damage.
Min. 70% of original value.
Within rated value.
2.0
1.0
1.0
2.0
2.0
1.0
1.0
2.0
m
m
0
0
200 to
500k
2
1
CdS
0.1 100 F
Criteria
W
Y
3.0
78L05
3.0
22Y220 F
S21E3.pdf 03.2.17
W
Y
5.0m
5.0m
8Y15V

Related parts for IRA-E940