HVP400 Hitron Electronics, HVP400 Datasheet

no-image

HVP400

Manufacturer Part Number
HVP400
Description
Universal Input Harmonic Correction Ac-dc N+1 Redundancy AND Active Current Sharing Enclosure BOX Single & Multi-output 400 Watts Internal Switching
Manufacturer
Hitron Electronics
Datasheet
H HiTRON
UNIVERSAL INPUT HARMONIC CORRECTION
AC-DC N+1 REDUNDANCY AND ACTIVE CURRENT SHARING
ENCLOSURE BOX SINGLE & MULTI-OUTPUT 400 WATTS
INTERNAL SWITCHING POWER SUPPLIES HVP400 SERIES
SPECIFICATION
INPUT SPECIFICATION
Input Voltage: Typ. 90-264Vac with PFC.
Input Connector: IEC320-3P & On/Off Switch.
Input Frequency: 47-63Hz.
Inrush Current: ≤ 30A @230Vac by active inrush
Input Current: 5.8A @ 115Vac, 2.6A @ 230Vac.
Dielectric Withstand: Meet IEC 60950-1.
EMI: Meet EN 55022 Class B.
Hold-up Time: Typ. 7.2-12mS @ 115Vac and
Power OK Signal: Available at VO1 & VO2.
Power Factor Correction: Meet IEC 61000-3-2 Harmonic
Over Temp. Protection: By thermostat.
Power Disable: Pin P3-2/open=shut-down.
Power On LED Indicator: Installed.
Earth Leakage: Less than 0.5mA @230Vac.
GENERAL SPECIFICATION
Efficiency: Typ. 65-70%.
Switching Frequency: Fixed frequency at 56K Hz.
Circuit Topology: PWM Fixed Frequency Forward Circuit.
Transient Response: Output voltage returns in
Safety Standard: UL 60950-1/EN 60950-1 Class I.
Hot Swappable: Available.
Power Density: 2.95 Watts / Cubic Inch.
Note: Due to requests in market and advances in technology, specifications subject to change without notification.
Typ. 35-42mS @ 230Vac.
Pin P3-2/short=Operation.
current limiter circuit.
less than 3mS following
a 25% load change.
Correction. PF typ. 0.92-0.98.
-63-
OUTPUT SPECIFICATION
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Connector: B-S/S-T/Molex MLX5045.
Output Wattage: Typ. 350-400 watts.
Line Regulation: Typ. 0.1%.
Load Regulation: Main VO1 typ. ±1.0%.
Noise & Ripple: Typ. 1.0% peak to peak.
OVP: Built-in at main VO1.
Remote Sense: Available at VO1 & VO2 rail.
Redundancy: Available for N+1 redundancy operation for
Current Sharing: 3rd-wire current sharing for VO1
OR-ing Diode: Installed in VO1,2,3.
Adjustability: Available at VO1 & VO2.
Output LED Indicator: Installed in VO1,2,3.
Overload Protection (OLP): Fully protected against
Operating Temperature: 0 to +50°C under 35 cfm forced
Storage Temperature: -20 to +85 °C.
Temperature Coefficient: Typ. 0.04% /°C.
Cooling: At least required 35 cfm forced cooling air flow
MTBF: 180,000 hours at full load and 25°C by
Construction: Enclosure box.
FEATURES:
ACCOMMODATE UNIVERSAL AC SOURCES
MEET IEC 61000-3-2 HARMONIC CORRECTION
THIRD-WIRE CURRENT SHARING
OR-ING DIODES FOR N+1 REDUNDANCY
HOT-SWAPPABLE
MEET UNIVERSAL SAFETY STANDARDS
EMI MEET EN 55022 CLASS B
CE MARKING COMPLIANCE
MIL-HDBK-217F spec.
Aux.VO2 typ. ±1-2% (Magnetic Amp.).
Aux.VO3 typ. ±3.0% (Couple Common Choke).
for full load operation.
sharing the load.
& VO2 rails.
output overload and short circuit.
Consult the factory for OLP setting.
air cooling for full load.
In application

Related parts for HVP400

HVP400 Summary of contents

Page 1

... H HiTRON UNIVERSAL INPUT HARMONIC CORRECTION AC-DC N+1 REDUNDANCY AND ACTIVE CURRENT SHARING ENCLOSURE BOX SINGLE & MULTI-OUTPUT 400 WATTS INTERNAL SWITCHING POWER SUPPLIES HVP400 SERIES SPECIFICATION INPUT SPECIFICATION Input Voltage: Typ. 90-264Vac with PFC. Input Connector: IEC320-3P & On/Off Switch. Input Frequency: 47-63Hz. ...

Page 2

... INPUT & OUTPUT CONNECTORS PIN ASSIGNMENT AC INPUT SINGLE O/P ASSIGNMENT AC-L AC-N AC-G VO1 CNTR & PIN P1-V1 Mating connector: P1 &P2 No-needed. P3 & P4 Molex MLX5051. DUAL OUTPUT MODEL NO. Volt. 3.3V HVP400-D033E 5.0V HVP400-D033I 12.0V HVP400-D033K 15.0V HVP400-D033M 24.0V HVP400-D050I 28.0V HVP400-D050K 36.0V HVP400-D050M 48.0V AUX. VO2 @▲◇#≡⊙ ≡ @★# ⊙ ...