Figure 23 Replacement
Figure 23a(s). Generic Machine Interface, MINI-SCREEN MSC..-1S2E Systems with the MSA-RM-1 relay pack
MSC..-1S..E

P/N 68980
L (V ac)
+ (V dc)
or
for Power Monitoring
MPCE1
in primary manual.
EDM as described
MPCE 1 MPCE 2
MPCE 1
Optional hookup
Machine
Control
Circuit
MPCE2
MPCE 2
Supplement: MINI-SCREEN Models with Selectable Trip/Latch Output
MINI-SCREEN Control Box
L (V ac) or + (V dc)
N (V ac) or – (V dc)
Relay Module
TB4
TB2
TB2
MSA-RM-1
MSC..-1S2E
See Figure 5
FSD2
FSD1
Mon a
Mon b
KEY 1
KEY 2
SSD
AUX
PE
Jumper Mon a and
Mon b for no
EDM monitoring
NOTE: See Sections
2.10(s) and 3.2.1.1(s) on
the installation of the
Key Reset switch.
FSD2
FSD1
SSD
TB1
TB1
TB1
TB1
*Arc Suppressor,
see warning at right
Earth Ground
MPCE
MSCE
MPCE
*
*
2
*
1
N (V ac)
– (V dc)
or
Banner Engineering Corp. • Minneapolis, MN U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
User must comply with all product manuals
and relevant regulations.
All MINI-SCREEN System output
contacts (FSD1, FSD2, and SSD)
must be used. The generalized wiring
configuration shown here is provided
only to illustrate the importance of proper
installation. The actual details of wiring of
the MINI-SCREEN system to any particular
machine is solely the responsibility of the
installer and end user.
If arc suppressors are used, they must
be installed as shown across the coils
of the safety relays. Never install arc
suppressors directly across the output
contacts of any safeguarding device.
WARNING . . .
WARNING . . .
WARNING . . .
Suppressors