ATA6836 ATMEL Corporation, ATA6836 Datasheet - Page 8

no-image

ATA6836

Manufacturer Part Number
ATA6836
Description
Hex Half-bridge Driver with Serial Input Control
Manufacturer
ATMEL Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATA6836-PXQW
Manufacturer:
ATMEL
Quantity:
3 500
Part Number:
ATA6836-PXQW
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
ATA6836C
Manufacturer:
TEMIC
Quantity:
46
Part Number:
ATA6836C
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
ATA6836C-PXQW
Manufacturer:
ATMEL
Quantity:
5 000
Part Number:
ATA6836C-PXQW
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
ATA6836C-TIQY
Manufacturer:
AMD
Quantity:
3 340
Part Number:
ATA6836C-TIQY
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Table 3-3.
8
Bit 15
(SI)
H
Bit 14
(SCT)
ATA6836 [Preliminary]
H
Status of the Input Register After Power on Reset
Bit 13
(OLD)
H
Bit 12
(HS6)
Table 3-2.
L
Note:
Bit
10
11
12
13
14
15
0
1
2
3
4
5
6
7
8
9
Bit 11
(LS6)
L
Bit 0 to 15 = high: overtemperature shutdown
Output (Status)
Bit 10
(HS5)
Status HS1
Status HS2
Status HS3
Status HS4
Status HS5
Status HS6
Status LS1
Status LS2
Status LS3
Status LS4
Status LS5
Status LS6
Output Data Protocol
Register
L
SCD
PSF
INH
TP
(LS5)
Bit 9
L
(HS4)
Bit 8
Function
Temperature prewarning: high = warning
(overtemperature shutdown see remark below)
Normal operation: high = output is on, low = output is off
Open-load detection: high = open load, low = no open load
(correct load condition is detected if the corresponding output is
switched off)
Normal operation: high = output is on, low = output is off
Open-load detection: high = open load, low = no open load
(correct load condition is detected if the corresponding output is
switched off)
Description see LS1
Description see HS1
Description see LS1
Description see HS1
Description see LS1
Description see HS1
Description see LS1
Description see HS1
Description see LS1
Description see HS1
Short circuit detected: set high, when at least one output is switched off
by a short circuit condition
Inhibit: this bit is controlled by software (bit SI in input register) and
hardware inhibit (pin INH). High = standby, low = normal operation
Power supply fail: undervoltage at pin VS detected
L
(LS4)
Bit 7
L
(HS3)
Bit 6
L
(LS3)
Bit 5
L
(HS2)
Bit 4
L
(LS2)
Bit 3
L
(HS1)
Bit 2
L
4952B–AUTO–07/07
(LS1)
Bit 1
L
(SRR)
Bit 0
L

Related parts for ATA6836