CN6880 Kontron, CN6880 Datasheet - Page 3

no-image

CN6880

Manufacturer Part Number
CN6880
Description
Manufacturer
Kontron
Datasheet
3
Mechanical Characteristics
Operation Power
Temperature
Humidity
Altitude
Shock and Vibration and Bump
Compliance / Regulatory
Electromagnetic Compatibility (EMC)
and Interference (EMI)
Safety
Technical Information
CORPORATE OffICES
Europe, Middle East & Africa
Oskar-von-Miller-Str. 1
85386 Eching/Munich
Germany
Tel.: +49 (0)8165/ 77 777
Fax: +49 (0)8165/ 77 279
info@kontron.com
Single slot ATCA blade
Management
Payload:
Meets test profile based on GR-63, EN 300 019-2-3 Class 3.1E, EN 300 019-2-2 Class 2.3
Air Flow: TBD
Operating short term:
Operating long term:
Non-operating:
The product meets test profile based on GR-63, EN 300 019-2-3 Class 3.1E, EN 300 019-2-2 Class 2.3 and EN 300 019-2-1
Class 1.2
Operating:
Non-Operating:
Designed to meet the following requirements according to Belcore GR-63, section 4.1.3:
Operating:
Non-Operating:
Test profile based on EN 300 019-2-3, class 3.2
Shock profile: 11 ms half sine, 3 g, 3 shocks in each direction.
Meets Operational Swept Sine Vibration: test profile based on GR-63, clause 5.4.2, and ETSI EN 300 019-2-3, class 3.2.
(5 to 200 Hz at 0.2 g)
Meets Operational Random Vibration: test profile based on ETSI EN 300 019-2-3, class 3.2
• 5 Hz to 10 Hz @ +12 dB/oct (slope up)
• 10 Hz to 50 Hz @ 0.02 m2/s3 (0.0002 g2/ Hz) (flat)
• 50 Hz to 100 Hz @ -12 dB/oct (slope down)
• 30 minutes per each 3 axes
Free Fall: designed to meet Bellcore GR-63, Section 5.3.
• Packaged -1000 mm, six surfaces, three edges and four corners
• Unpackaged - 100 mm, two sides and two bottom corners
Designed to meet the following environmental, safety and EMC requirements:
EN 300 019; Telcordia GR-63; Telcordia SR-3580 level 3; Telcordia GR-1089; Designed to meet Class B emissions limits,
for a system-level goal of Class A with 6 dB margin
Meets all emission and immunity requirements of FCC Part 15, GR-1089, EN 300 386, EN 55022 and EN 55024
Meets GR-1089 (3.1.2) radiated emissions requirements from 10 kHz to 10 GHz, class A
Meets GR-1089 conducted emissions requirements from 10 kHz to 30 MHz, class A
Meets all requirements of UL/CSA/EN/IEC 60950-1
Compliant with the Low Voltage Directive, EC Council Directive 2006/95/EC
Meets electric strength requirements (5.2): Primary to Chassis 1 kV, Primary to secondary 1kV.
(May be higher if maximum working voltage of converter is greater than 72 Vdc)
Meets the Telcordia GR-63 material flammability requirement UL 94V-0, or V-1 with oxygen index of 28 % or greater
North America
14118 Stowe Drive
Poway, CA 92064-7147
USA
Tel.: +1 888 294 4558
Fax: +1 858 677 0898
info@us.kontron.com
-300 m to 4,000 m (13123 ft) (GR63 4.1.3) at aisle-ambient temperature of 40 deg C; may require
-300 m to 14,000 m (45931.2 ft)
additional cooling above 1800m (5905ft)
TBD Wmax., TBD W typ.
TBD W max.,TBD W typ.
5%-93% (non-condensing) at 40°C
5%-93% (non-condensing) at 40°C
0°C to +60 °C
0°C to +45 °C
-40 °C to +85 °C
Asia Pacific
17 Building,Block #1,ABP.
188 Southern West 4th Ring Road
Beijing 100070, P.R.China
Tel.: + 86 10 63751188
Fax: + 86 10 83682438