S-35390A Seiko Instruments, S-35390A Datasheet - Page 31

no-image

S-35390A

Manufacturer Part Number
S-35390A
Description
2-Wire Real Time Clock
Manufacturer
Seiko Instruments
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
S-35390A
Manufacturer:
SEIKO/精工
Quantity:
20 000
Part Number:
S-35390A-I8T1G
Manufacturer:
SEIKO
Quantity:
10 000
Part Number:
S-35390A-I8T1G
Manufacturer:
SEIKO/精工
Quantity:
20 000
Part Number:
S-35390A-J8T1G
Manufacturer:
SEK
Quantity:
1 000
Part Number:
S-35390A-J8T1G
Manufacturer:
SEK
Quantity:
1 000
Part Number:
S-35390A-J8T1G
Manufacturer:
SEIKO/精工
Quantity:
20 000
Company:
Part Number:
S-35390A-J8T1G
Quantity:
194
Company:
Part Number:
S-35390A-J8T1G
Quantity:
521
Company:
Part Number:
S-35390A-J8T1U
Quantity:
50 000
Company:
Part Number:
S-35390A-T8T1
Quantity:
2 940
Part Number:
S-35390A-T8T1G
Manufacturer:
SEIKO
Quantity:
18 700
Part Number:
S-35390A-T8T1G
Manufacturer:
SEIKO
Quantity:
10 000
Part Number:
S-35390A-T8T1G
Manufacturer:
SEIKO
Quantity:
20 000
Company:
Part Number:
S-35390A-T8T1G
Quantity:
290
Rev.1.2
1. Initialization flow at power-on
Example of Software Processing
_00
NO
command transmission
command transmission
Status register_1 setting
Status register_2 setting
Realtime data setting
command transmission
command transmission
INT1 register setting
YES
to reset flag
Power-on
TEST = 1
Write “1”
START
POC = 1
BLD = 1
END
or
NO
*1
YES
Figure 33 Initialization Flow
Seiko Instruments Inc.
*1.
If conditions are poor (e.g., in a noisy environment)
and there is a high probability that commands
transmitted via serial communication will be
garbled, it is recommended to verify the TEST flag.