S-24CS08A Seiko Instruments, S-24CS08A Datasheet - Page 19

no-image

S-24CS08A

Manufacturer Part Number
S-24CS08A
Description
(S-24CS0xA) 2-Wire CMOS Serial EPROM
Manufacturer
Seiko Instruments
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
S-24CS08A
Manufacturer:
N/A
Quantity:
20 000
Part Number:
S-24CS08AFJ
Manufacturer:
SEKIO
Quantity:
20 000
Part Number:
S-24CS08AFJ-TB
Manufacturer:
SEIKO
Quantity:
1 601
Part Number:
S-24CS08AFJ-TB
Manufacturer:
SEK
Quantity:
1 500
Part Number:
S-24CS08AFJ-TB-1G
Manufacturer:
SHARP
Quantity:
1 831
Part Number:
S-24CS08AFJ-TB-1G
Manufacturer:
SII/精工
Quantity:
20 000
Part Number:
S-24CS08AFJ-TB-1GE
Manufacturer:
SEIKO
Quantity:
9 041
Part Number:
S-24CS08AFJ-TB-1GE
Manufacturer:
SEIKO
Quantity:
20 000
Company:
Part Number:
S-24CS08AFJ-TB-1GE
Quantity:
202
Part Number:
S-24CS08AFJ-TBK-1G
Manufacturer:
SII/精工
Quantity:
20 000
www.DataSheet4U.com
Rev.2.0
8. Address Increment Timing
Write inhibition function at low power voltage
The S-24CS01A/02A/04A/08A have a detection circuit for low power voltage. The detection circuit cancels a
write instruction when the power voltage is low or the power switch is on. The detection voltage is 1.75 V
typically and the release voltage is 2.05 V typically, the hysteresis of approximate 0.3 V thus exists. (See
Figure 19.)
When a low power voltage is detected, a write instruction is canceled at the reception of a stop condition.
When the power voltage lowers during a data transmission or a write operation, the date at the address of
the operation is not assured.
The timing for the automatic address increment is the falling edge of the SCL clock for the 8th bit of the
read data in read operation and the the falling edge of the SCL clock for the 8th bit of the received data in
write operation.
SCL
SDA
SCL
SDA
_10
Power supply voltage
R / W=1
R / W=0
8
8
Figure 17 Address Increment Timing in Reading
Figure 18 Address Increment Timing in Writing
Figure 19 Operation at low power voltage
ACK Output
ACK Output
Detection voltage (-V
9
9
1.75 V typ.
Seiko Instruments Inc.
D7 Output
D7 Input
DET
1
1
)
0.3 V approximately
Hysteresis width
Write Instruction
cancel
2-WIRE CMOS SERIAL E
Address Increment
D0 Output
Release voltage (+V
Address Increment
D0 Input
S-24CS01A/02A/04A/08A
8
8
2.05 V typ.
ACK Output
DET
)
9
9
2
PROM