MT9041B Mitel Networks Corporation, MT9041B Datasheet - Page 18

no-image

MT9041B

Manufacturer Part Number
MT9041B
Description
T1/E1 System Synchronizer
Manufacturer
Mitel Networks Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MT9041BP
Manufacturer:
MTTEL
Quantity:
4 130
Part Number:
MT9041BP
Manufacturer:
MTTEL
Quantity:
4 130
Part Number:
MT9041BP
Manufacturer:
ZARLINK
Quantity:
20 000
Company:
Part Number:
MT9041BP
Quantity:
180
Part Number:
MT9041BP1
Manufacturer:
ZARLINK
Quantity:
189
Part Number:
MT9041BP1
Manufacturer:
ZARLINK
Quantity:
20 000
Part Number:
MT9041BPR
Manufacturer:
CONEXANT
Quantity:
517
Part Number:
MT9041BPR1
Manufacturer:
ZARLINK
Quantity:
189
MT9041B
Advance Information
† Notes:
Voltages are with respect to ground (V
) unless otherwise stated.
SS
Supply voltage and operating temperature are as per Recommended Operating Conditions.
Timing parameters are as per AC Electrical Characteristics - Timing Parameter Measurement Voltage Levels
1. Normal Mode selected.
2. Freerun Mode selected.
3. 8kHz Frequency Mode selected.
4. 1.544MHz Frequency Mode selected.
5. 2.048MHz Frequency Mode selected.
6. Master clock input OSCi at 20MHz 0ppm.
7. Master clock input OSCi at 20MHz 32ppm.
8. Master clock input OSCi at 20MHz 100ppm.
9. Selected reference input at 0ppm.
10. Selected reference input at 32ppm.
11. Selected reference input at 100ppm.
12. For Freerun Mode of 0ppm.
13. For Freerun Mode of 32ppm.
14. For Freerun Mode of 100ppm.
15. For capture range of 230ppm.
16. For capture range of 198ppm.
17. For capture range of 130ppm.
18. 25pF capacitive load.
19. OSCi Master Clock jitter is less than 2nspp, or 0.04UIpp
where1UIpp=1/20MHz.
20. Jitter on reference input is less than 7nspp.
21. Applied jitter is sinusoidal.
22. Minimum applied input jitter magnitude to regain synchronization.
23. Loss of synchronization is obtained at slightly higher input
jitter amplitudes.
24. Within 10ms of the state, reference or input change.
25. 1UIpp = 125us for 8kHz signals.
26. 1UIpp = 648ns for 1.544MHz signals.
27. 1UIpp = 488ns for 2.048MHz signals.
28. 1UIpp = 323ns for 3.088MHz signals.
29. 1UIpp = 244ns for 4.096MHz signals.
30. 1UIpp = 122ns for 8.192MHz signals.
31. 1UIpp = 61ns for 16.384MHz signals.
32. No filter.
33. 40Hz to 100kHz bandpass filter.
34. With respect to reference input signal frequency.
35. After a RST or TRST.
36. Master clock duty cycle 40% to 60%.