PP46-49 Spectrum Control Inc., PP46-49 Datasheet - Page 3

no-image

PP46-49

Manufacturer Part Number
PP46-49
Description
Switched And Fused Filtered Power Entry Modules
Manufacturer
Spectrum Control Inc.
Datasheet
48
Switched and Fused Filtered
Power Entry Modules
For Medical or General Purpose Applications
66-67-BSF/66-67-SSF Series
Features
Specifications
Note: Test Voltage: 1500VAC one minute, line to ground
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
66-XXX-020-0-12
66-XXX-020-0-04
66-XXX-020-0-14
66-XXX-020-0-06
66-XXX-020-1-12
66-XXX-020-1-04
66-XXX-020-1-14
66-XXX-020-1-06
66-XXX-020-4-12
66-XXX-020-4-04
66-XXX-020-4-14
66-XXX-020-4-06
66-XXX-040-0-12
66-XXX-040-0-04
66-XXX-040-0-14
66-XXX-040-0-06
66-XXX-040-1-12
66-XXX-040-1-04
66-XXX-040-1-14
66-XXX-040-1-06
66-XXX-040-4-12
66-XXX-040-4-04
66-XXX-040-4-14
66-XXX-040-4-06
66-XXX-060-0-12
66-XXX-060-0-04
66-XXX-060-0-14
66-XXX-060-0-06
66-XXX-060-1-12
66-XXX-060-1-04
66-XXX-060-1-14
66-XXX-060-1-06
66-XXX-060-4-12
66-XXX-060-4-04
66-XXX-060-4-14
66-XXX-060-4-06
Metric and North American fuse holders available
Fuse holder and a double pole power ON/OFF switch
provides a convenient/compact package
Suitable for products that must conform
to FCC and FTZ requirements
Meets over voltage category II of IEC 664
and complies with IEC 950
Provides susceptibility protection without the leakage
current associated with line-to-ground capacitors
Designed to meet requirements for non-patient
and patient care equipment
Metal case provides effective EMI shielding
Easy access fuse drawer - space for spare fuse
Flange-mounted or snap-in styles available
for quick mounting
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 49)
Model*
Insulation Resistance: 300 M min. at 500VDC
Voltage Drop: 1V max. at rated current
50/60Hz
Voltage Current Current
Rated
VAC
250
Rated Leakage
2A
4A
6A
.075mA
.075mA
.075mA
(Max.)
.01mA
0.1mA
.01mA
.01mA
.01mA
0.1mA
NONE
470pF
330pF
NONE
470pF
330pF
NONE
470pF
330pF
C
Y
Capacitance
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
C
X1
Tested and found to be
0.22uF
0.22uF
0.22uF
0.22uF
0.22uF
0.22uF
0.22uF
0.22uF
0.22uF
0.22uF
0.22uF
0.22uF
0.22uF
0.22uF
0.22uF
0.22uF
0.22uF
0.22uF
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
IAW VDE 0565 Part 3
C
X2
Induct.
10.5mH
Temp.
4.2mH
1.6mH
(L
Weight: 130g
Inlet: Compatible with IEC-320
B(S) = Bolt-in terminals or (Snap-in terminals)
1
)
(Max.)
Rise
40°C
45°C
67-XXX-020-0-12
67-XXX-020-0-04
67-XXX-020-0-14
67-XXX-020-0-06
67-XXX-020-1-12
67-XXX-020-1-04
67-XXX-020-1-14
67-XXX-020-1-06
67-XXX-020-4-12
67-XXX-020-4-04
67-XXX-020-4-14
67-XXX-020-4-06
67-XXX-040-0-12
67-XXX-040-0-04
67-XXX-040-0-14
67-XXX-040-0-06
67-XXX-040-1-12
67-XXX-040-1-04
67-XXX-040-1-14
67-XXX-040-1-06
67-XXX-040-4-12
67-XXX-040-4-04
67-XXX-040-4-14
67-XXX-040-4-06
67-XXX-060-0-12
67-XXX-060-0-04
67-XXX-060-0-14
67-XXX-060-0-06
67-XXX-060-1-12
67-XXX-060-1-04
67-XXX-060-1-14
67-XXX-060-1-06
67-XXX-060-4-12
67-XXX-060-4-04
67-XXX-060-4-14
67-XXX-060-4-06
Applications
Circuit Diagram
Note: C
omitted on 66/67
B(S)F-XXX-1-X Filters
Medical equipment
Industrial equipment
Telecommunications equipment
Measuring and testing instruments
Model*
Y1
and C
Y2
50/60Hz
Voltage Current Current
Rated
VAC
capacitors
125
Rated Leakage
2A
4A
6A
N
L
E
0.04mA
0.04mA
.005mA
0.05mA
.005mA
0.05mA
0.04mA
.005mA
0.05mA
(Max.)
* Substitute BSF or SSF for XXX
BSF - Bolt-In Switched and Fused
SSF - Snap-In Switched and Fused
NONE
470pF
330pF
NONE
470pF
330pF
NONE
470pF
330pF
C
Y
R
Capacitance
C
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
Digital equipment (including
switching power supplies)
General purpose filter for
susceptibility or high frequency
“clean up” applications
X1
C
X1
L
1
0.22uF
0.22uF
0.22uF
0.22uF
0.22uF
0.22uF
0.22uF
0.22uF
0.22uF
0.22uF
0.22uF
0.22uF
0.22uF
0.22uF
0.22uF
0.22uF
0.22uF
0.22uF
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
C
X2
C
X2
C
C
Y1
Y2
Induct.
10.5mH
Temp.
4.2mH
1.6mH
(L
1
)
(Max.)
Rise
40°C
45°C
L
E
N

Related parts for PP46-49