TA2.0 High Energy Devices, LLC, TA2.0 Datasheet

no-image

TA2.0

Manufacturer Part Number
TA2.0
Description
Triggered Spark Gaps
Manufacturer
High Energy Devices, LLC
Datasheet
Features
Applications
Standard Voltages
Devices in the TA/TB/TG221-226 Series with other main static breakdown
voltages in the 1.0-60.0kV range are available upon request.
Tight main static breakdown voltage tolerance
(+10% - TA & TB series)
Adjustable main static breakdown voltage (TG221
to TG226)
Rugged ceramic-metal construction
Refractory metal electrodes
Corrosion-resistant stainless steel external surfaces
(TB series)
High current surge generators
Exploding bridge wire systems
Crowbars
Flashlamp triggers
Series/
Part Number Breakdown Voltage (Nom)
TA
TB
TG221
TG222
TG224
TG225
TG226
Main Static
18.0-40.0
18.0-40.0
35.0-60.0
1.0-20.0
1.0-20.0
10.0
15.0
10.0
15.0
20.0
25.0
1.0
2.0
5.0
7.0
2.5
5.0
www.highenergydevices.com
Unit
kV
kV
kV
kV
kV
kV
kV
kV
kV
kV
kV
kV
kV
kV
kV
kV
kV
Description
Ordering Information
High Energy Devices’ Triggergaps are high energy
spark gaps that are capable of switching stored energy
in a fraction of a microsecond upon command.
Triggergaps require no standby power, are extremely
rugged, and require only a low-energy, high-voltage
triggering pulse. The miniature TA series (1.0-15.0kV)
provides switching capability for pulses with energy
content as high as 50 joules. The larger TB series (2.5-
25.0kV) will reliably switch pulses with up to 300 joules
of energy. The TG221 to 226 (1.0-60.0kV) can switch
pulses with energy contents of up to 6,000 joules and
feature adjustable main static breakdown voltages.
A complete part number is represented by the digits
below. Main static breakdown voltages are expressed
in kV. For example, TA5.0 is a 5kV TA series device
and TB25.0 is a 25kV TB series device.
Product Series /
Part Number
TAX.X
TAXX.X
TBX.X
TGXX.X
TG221 to 226
TA/TB/TG221-226 Series
Triggered Spark Gaps
Breakdown Voltage
detailed specifications
As shown in the
Main Static
10.0-15.0kV
10.0-25.0kV
1.0-9.0kV
2.5-9.0kV
1 of 6

Related parts for TA2.0

TA2.0 Summary of contents

Page 1

Features Tight main static breakdown voltage tolerance • (+10 & TB series) Adjustable main static breakdown voltage (TG221 • to TG226) Rugged ceramic-metal construction • Refractory metal electrodes • Corrosion-resistant stainless steel external surfaces • (TB series) Applications ...

Page 2

... TB2.5 Symbol Min Nom Max Min E 2.25 2.50 2.75 4 0.8 - 2.0 1 3.1 - 1.8 3.2 trig - - 1,000 - - 1,000 - 150 - - 150 - - 150 - - www.highenergydevices.com TA2.0 TA5.0 Nom Max Min Nom Max Units 2.0 2.2 4.5 5.0 5.5 - 1.7 1.2 - 4.2 - 2.5 3 0.760 0.823 0.697 0.760 0.823 inches - - 1,000 - - shots - - TA10.0 TA15.0 Nom Max Min Nom Max Units 10.0 11.0 13.5 15.0 16.5 - 8.5 7 ...

Page 3

Specifications (@ Parameter Conditions Device Specifications Main Static Breakdown Voltage 100V/s Applied Voltage (1) Trigger Voltage t =0.5µs, PW=3.0µs r Dimension A Dimension B Dimension C Life Ratings 5,000A (2) Discharge Life Pulse Energy (as shown) Pulse Energy ...

Page 4

TA/TB/TG221-226 Series Specifications (@ Parameter Conditions Device Specifications Main Static Breakdown Voltage 100V/s Applied Voltage Dimension A Dimension B Life Ratings Peak Current PW=30µs 5,000A (3) Discharge Life Pulse Energy (as shown) Pulse Energy (4) Cumulative Charge Coulomb ...

Page 5

TA Series TB Series MECHANICAL DIMENSIONS mm/(inches) www.highenergydevices.com TA/TB/TG221-226 Series ...

Page 6

... HIGH ENERGY DEVICES, LLC MAKES NO REPRESENTATIONS OR WARRANTIES WITH RESPECT TO THE ACCURACY HIGH ENERGY DEVICES, LLC MAKES NO REPRESENTATIONS OR WARRANTIES WITH RESPECT TO THE ACCURACY OR COMPLETENESS OF THE CONTENTS OF THIS PUBLICATION AND RESERVES THE RIGHT TO MAKE CHANGES OR COMPLETENESS OF THE CONTENTS OF THIS PUBLICATION AND RESERVES THE RIGHT TO MAKE CHANGES TO SPECIFICATIONS AND PRODUCT DESCRIPTIONS AT ANY TIME WITHOUT NOTICE ...