SC9641 Silan, SC9641 Datasheet - Page 7

no-image

SC9641

Manufacturer Part Number
SC9641
Description
CD Digital Signal Processor
Manufacturer
Silan
Datasheet
www.DataSheet4U.com
(Continued)
HANGZHOU SILAN MICROELECTRONICS CO.,LTD
Http: www.silan.com.cn
COMMAND
(HEX)
0C
0F
PARAMETER
XXXXXXXX
00000010
00000011
00000100
00000101
00000110
00000111
00010000
00010001
00010010
00010011
00010100
00010101
00100000
00100001
00100010
(BIN)
Set shield time of the motor error signal (the initial value is 40H), the
parameter is 00H~FFH, the internal reference is 8ms, so the shield time is
0~2 seconds; if the motor rotate speed is detected in the set range, and
detect the shield time of motor error signal is exceed, the system consider
the servo is abnormally and need restart.
Start play, if not read TOC, then store the TOC data; when play at the
export section, if the sub-controller at normal play state, the system will
receive the command of master controller.
read and save TOC information again, and stay in the lay in section.
Pause.
Fast play, at this time, playing at FAST_STEP, and FAST_TIME interval,
after fast forward to export section, it entry pause mode, wait for the next
command.
Fast backward, playing at FAST_STEP, and FAST_TIME interval. After
fast backward to import section, it enter pause mode and wait for the
command of master controller.
Stop play, and switch bare head to inside track.
If it is in the lay in section, then jump out the lay in section, and play at the
target track.
The target track set command: 0X11
If it is in the lay in section, then jump out the lay in section, and play at the
target track.
The target track set command: 0X12, 0X13, 0X14
If it is in the lay in section, then jump out the lay in section, and play at the
relative time of target track.
Set command: 0X11, 0X12, 0X13, 0X14
Initialize the servo
Closed CD data output.
Open CD data output
Jump to the next session; if there are a next session, then store the start
address of program to the NEXT_AMIN, NEXT_ASEC, NEXT_AFRM; If
there are no next session, then the NEXT_AMIN, NEXT_ASEC,
NEXT_AFRM remain original value or is 0XFF.
Stop at the former play point, the sled motor will not return.
This command used for control sled motor in or out after servo stop:
5FH + 81H, 0FH + 21H
5FH + 7FH, 0FH + 21H Sled motor sled outside.
5FH + 00H, 0FH + 21H Sled motor stop.
FUNCTION DESCRIPTIONS
Sled motor sled inside.
REV:1.0
(To be continued)
Page 7 of 15
SC9641
2008.03.24

Related parts for SC9641