HD1-15531B Intersil Corporation, HD1-15531B Datasheet
HD1-15531B
Available stocks
Related parts for HD1-15531B
HD1-15531B Summary of contents
Page 1
... The HD-15531/883 can also be used in many party line digi- tal data communications applications, such as a local area network or an environmental control system driven from a single twisted pair or fiber optic cable throughout a building. 1.25MBIT/SEC o C HD1-15531/883 © Intersil Corporation 1999 5-170 2.5MBIT/SEC PKG. NO. HD1-15531B/883 F40.6 2962.1 File Number ...
Page 2
Pinout SERIAL DATA OUT SYNCHR DATA SEL SYNCHR CLK SEL BIPOLAR ZERO IN UNIPOLAR DATA IN DECODER SHIFT CLK DECODER PARITY SEL DECODER RESET Block Diagrams GND 21 MASTER RESET 22 SEND CLK OUT 24 ENCODER CLK ...
Page 3
Block Diagrams (Continued) SYNCHRONOUS 13 UNIPOLAR DATA IN 12 BIPOLAR ONE IN 11 BIPOLAR ZERO IN 9 DECODER CLK 15 SYNCHRONIZER DECODER CLK SELECT 8 SYNCHRONOUS CLK 10 SYNCHRONOUS CLK SELECT 22 MASTER RESET HD-15531/883 DECODER 7 8 SYNCHRONOUS DATA ...
Page 4
Absolute Maximum Ratings Supply Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
Page 5
TABLE 2. HD-15531/883, HD-15531B/883 AC ELECTRICAL PERFORMANCE SPECIFICATIONS (Continued) (NOTE 2) PARAMETER SYMBOL CONDI-TIONS Encoder Data FED VCC = 4.5V and 5.5V Rate Master Reset TMR VCC = 4.5V and 5.5V Pulse Width Shift Clock TE1 VCC = 4.5V and ...
Page 6
TABLE 2. HD-15531/883, HD-15531B/883 AC ELECTRICAL PERFORMANCE SPECIFICATIONS (Continued) (NOTE 2) PARAMETER SYMBOL CONDI-TIONS Take Data TD7 VCC = 4.5V and 5.5V Delay (ON) Serial Data TD8 VCC = 4.5V and 5.5V Out Delay Sync Delay TD9 VCC = 4.5V ...
Page 7
... VCC GND VCC FO GND GND A VCC NC A GND GND VCC VCC GND NOTES: 1. VCC = 5.5V 0.5V. 2. VIH = 4.5V 10%. 3. VIL = -0.2V to +0.4V 47k 5 100kHz 10%. HD-15531/883 HD1-15531/883 CERDIP ...
Page 8
... All Intersil semiconductor products are manufactured, assembled and tested under ISO9000 quality systems certification. Intersil products are sold by description only. Intersil Corporation reserves the right to make changes in circuit design and/or specifications at any time without notice. Accordingly, the reader is cautioned to verify that data sheets are current before placing orders. Information furnished by Intersil is believed to be accurate and reliable. However, no responsibility is assumed by Intersil or its subsidiaries for its use ...