AN1910 Freescale Semiconductor / Motorola, AN1910 Datasheet - Page 21

no-image

AN1910

Manufacturer Part Number
AN1910
Description
3-Phase AC Motor Control with V/Hz Speed Closed Loop Using the DSP56F80X
Manufacturer
Freescale Semiconductor / Motorola
Datasheet
6.2.5 PWM Fault A ISR
6.2.6 ADC Conversion Complete ISR
6.2.7 ADC High Limit ISR
6.2.8 ADC Low Limit ISR
6.2.9 Timer OC LED ISR
6.2.10 Timer OC Ramp ISR
This
DC_Bus_OverCurrent according to fault input pin level in case of over voltage or over current in
DC-Bus line.
Name of callback function in code: pwm_Fault_A_ISR(void).
This subroutine is called at PWM A (or PWM in case of DSP56F803) Fault Interrupt.
The following analog inputs are read:
Also the detection of faults caused by Over heating and Under voltage is performed in this subroutine.
Name of callback function in code: ADC_Callback_ISR.
This subroutine is called at ADC conversion completion.
This subroutine turns on the resistive brake in DC-Bus link when actual voltage in DC-Bus u_dc_bus
is higher than BRAKE_HIGH_LIMIT.
Name of callback function in code: ADC_High_Limit_CallBack_ISR.
This subroutine turns off the resistive brake in DC-Bus link when actual voltage in DC-Bus u_dc_bus
is lower than BRAKE_LOW_LIMIT.
Name of callback function in code: ADC_Low_Limit_CallBack_ISR.
This subroutine takes care of LED handling.
Name of callback function in code: LedISR (void).
Access frequency is defined by constant TMR_1_PERIOD in definition section of program.
This subroutine takes care of Speed ramp calculation.
Name of callback function in code: RampISR (void).
Access frequency is defined by constant TMR_2_PERIOD in definition section of program.
disable
DC-Bus Voltage
DC-Bus Current
Temperature of Power Stage Module
PWM
3-Phase AC Motor Control with V/Hz Speech Closed Loop
Freescale Semiconductor, Inc.
module
For More Information On This Product,
Go to: www.freescale.com
and
sets
DriveFaultStatus
|=
DC_Bus_OverVoltage
Software Design
21
or

Related parts for AN1910