EM638165 Etron Technology Inc., EM638165 Datasheet - Page 3

no-image

EM638165

Manufacturer Part Number
EM638165
Description
4Mega x 16 Synchronous DRAM (SDRAM)
Manufacturer
Etron Technology Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EM638165TS
Manufacturer:
台湾ETRON钰创
Quantity:
20 000
Part Number:
EM638165TS-6
Manufacturer:
ETRONTECH
Quantity:
5 380
Part Number:
EM638165TS-6
Manufacturer:
ETRONTECH
Quantity:
5 380
Part Number:
EM638165TS-6
Manufacturer:
EON
Quantity:
1 080
Part Number:
EM638165TS-61G
Manufacturer:
ETRONTECH
Quantity:
20 000
Part Number:
EM638165TS-6G
Manufacturer:
ETRON
Quantity:
2 289
Part Number:
EM638165TS-6G
Manufacturer:
ETRON
Quantity:
1 000
Part Number:
EM638165TS-6G
Manufacturer:
ETRONTECH
Quantity:
3
Part Number:
EM638165TS-6G
Manufacturer:
ETRONTECH
Quantity:
10 000
Part Number:
EM638165TS-6G
Manufacturer:
ETRON
Quantity:
20 000
Part Number:
EM638165TS-6G
0
Company:
Part Number:
EM638165TS-6G
Quantity:
1 080
Company:
Part Number:
EM638165TS-6G
Quantity:
972
Company:
Part Number:
EM638165TS-6G.
Quantity:
201
Part Number:
EM638165TS-6IG
Manufacturer:
ETRON
Quantity:
300
Part Number:
EM638165TS-6IG
Manufacturer:
ETRONTECH
Quantity:
10
Part Number:
EM638165TS-6IG
Manufacturer:
ETRONTECH
Quantity:
20 000
Pin Descriptions
Preliminary
BA0,BA1
Symbol
A0-A11
RAS#
CAS#
CLK
CKE
CS#
Type
Input
Input
Input
Input
Input
Input
Input
Clock: CLK is driven by the system clock. All SDRAM input signals are
sampled on the positive edge of CLK. CLK also increments the internal burst
counter and controls the output registers.
Clock Enable: CKE activates(HIGH) and deactivates(LOW) the CLK signal. If
CKE goes low synchronously with clock(set-up and hold time same as other
inputs), the internal clock is suspended from the next clock cycle and the state
of output and burst address is frozen as long as the CKE remains low. When all
banks are in the idle state, deactivating the clock controls the entry to the Power
Down and Self Refresh modes. CKE is synchronous except after the device
enters Power Down and Self Refresh modes, where CKE becomes
asynchronous until exiting the same mode. The input buffers, including CLK,
are disabled during Power Down and Self Refresh modes, providing low
standby power.
Bank Select: BA0,BA1 input select the bank for operation.
Address Inputs: A0-A11 are sampled during the BankActivate command (row
address A0-A11) and Read/Write command (column address A0-A7 with A10
defining Auto Precharge) to select one location out of the 2M available in the
respective bank. During a Precharge command, A10 is sampled to determine if
all banks are to be precharged (A10 = HIGH). The address inputs also provide
the op-code during a Mode Register Set command.
Chip Select: CS# enables (sampled LOW) and disables (sampled HIGH) the
command decoder. All commands are masked when CS# is sampled HIGH.
CS# provides for external bank selection on systems with multiple banks. It is
considered part of the command code.
Row Address Strobe: The RAS# signal defines the operation commands in
conjunction with the CAS# and WE# signals and is latched at the positive edges
of CLK. When RAS# and CS# are asserted "LOW" and CAS# is asserted
"HIGH," either the BankActivate command or the Precharge command is
selected by the WE# signal. When the WE# is asserted "HIGH," the
BankActivate command is selected and the bank designated by BS is turned on
to the active state. When the WE# is asserted "LOW," the Precharge command
is selected and the bank designated by BS is switched to the idle state after the
precharge operation.
Column Address Strobe: The CAS# signal defines the operation commands in
conjunction with the RAS# and WE# signals and is latched at the positive edges
of CLK. When RAS# is held "HIGH" and CS# is asserted "LOW," the column
access is started by asserting CAS# "LOW." Then, the Read or Write command
is selected by asserting WE# "LOW" or "HIGH."
Table 1. Pin Details of EM638165
BA1
0
0
1
1
3
Description
BA0
0
1
0
1
Rev 0.6
EM638165
Select Bank
BANK #A
BANK #B
BANK #C
BANK #D
Feb. 2001