FAN4800A Fairchild Semiconductor, FAN4800A Datasheet - Page 21

no-image

FAN4800A

Manufacturer Part Number
FAN4800A
Description
Fan4800a/c, Fan4801/1s/2/2l Pfc/pwm Controller Combination
Manufacturer
Fairchild Semiconductor
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
FAN4800AMY
Manufacturer:
NEC
Quantity:
6 219
Company:
Part Number:
FAN4800AMY
Quantity:
300
Part Number:
FAN4800ANY
Manufacturer:
FSC
Quantity:
1 800
Part Number:
FAN4800ANY
Manufacturer:
FAI
Quantity:
4 925
Part Number:
FAN4800ANYG
Manufacturer:
FAIRCHILD/仙童
Quantity:
20 000
Part Number:
FAN4800ASMY
Manufacturer:
FAIRCHILD/仙童
Quantity:
20 000
Part Number:
FAN4800ASNY
Manufacturer:
FSC
Quantity:
9 926
Part Number:
FAN4800AUM
Manufacturer:
FSC
Quantity:
20 000
Part Number:
FAN4800AUM
0
Company:
Part Number:
FAN4800AUM
Quantity:
27 500
Company:
Part Number:
FAN4800AUM
Quantity:
5 000
Part Number:
FAN4800AUN
Manufacturer:
FAIRCHILD/仙童
Quantity:
20 000
Part Number:
FAN4800AUN
0
Company:
Part Number:
FAN4800AUN
Quantity:
4 500
© 2008 Fairchild Semiconductor Corporation
FAN4800A/C, FAN4801/1S/2/2L • Rev. 1.0.2
PWM Control (RAMP)
When the PWM section is used in current mode, RAMP
is generally used as the sampling point for a voltage,
representing the current in the primary of the PWM’s
output transformer. The voltage is derived either from a
current sensing resistor or a current transformer. In
voltage mode, RAMP is the input for a ramp voltage
generated by a second set of timing components
(R
peak value of approximately 6V. In voltage mode, feed
forward from the PFC output bus is an excellent way to
derive the timing ramp for the PWM stage.
Generating V
After turning on the FAN4800A/C, FAN4801/1S/2/2L at
11V, the operating voltage can vary from 9.3V to 28V.
The threshold voltage of the V
28V and its hysteresis is 1V. When V
OPFC is LOW, and the PWM section is not disturbed.
There are two ways to generate V
power supply around 15V or use bootstrap winding to
self-bias the FAN4800A/C, FAN4801/1S/2/2L system.
The bootstrap winding can be taped from the PFC
boost choke or the transformer of the DC-to-DC stage.
RAMP
, C
RAMP
) that have a minimum value of 0V and a
DD
DD
OVP comparator is
DD
DD
: use auxiliary
reaches 28V,
21
Leading/Trailing Modulation
Conventional PWM techniques employ trailing-edge
modulation, in which the switch turns on right after the
trailing edge of the system clock. The error amplifier
output is then compared with the modulating ramp up.
The effective duty cycle of the trailing edge modulation
is determined during the on-time of the switch.
In the case of leading-edge modulation, the switch is
turned off exactly at the leading edge of the system
clock. When the modulating ramp reaches the level of
the error amplifier output voltage, the switch is turned
on. The effective duty-cycle of the leading-edge
modulation is determined during off-time of the switch.