RUExxx Raychem, RUExxx Datasheet - Page 2

no-image

RUExxx

Manufacturer Part Number
RUExxx
Description
RUE Selection Guide
Manufacturer
Raychem
Datasheet
4
I
Part
number
RUE090
RUE110
RUE135
RUE160
RUE185
RUE250
RUE300
RUE400
RUE500
RUE600
RUE700
RUE800
RUE900
142
Hold
vs. temperature
RUE Devices
RUE
Radial Leaded
10.15
11.60
13.05
Maximum ambient operating temperatures (°C)
–40°
1.31
1.60
1.96
2.32
2.68
3.63
4.35
5.80
7.25
8.70
10.40
11.70
–20°
1.17
1.43
1.76
2.08
2.41
3.25
3.90
5.20
6.50
7.80
9.10
1.
Fill in the following information about the circuit:
Maximum ambient operating temperature
Normal operating current
Maximum operating voltage (RUE is 30 V max.)
Maximum interrupt current
2.
Look across the top of the table below to find the temperature that
most closely matches the circuit’s maximum ambient operating temper-
ature. Look down that column to find the value equal to or greater than
the circuit’s normal operating current. Now look to the far left of that
row to find the part number for the RUE device that will best accommo-
date the circuit.
The thermal derating curve located on the next page is a normalized
representation of the data in the table below.
10.35
1.04
1.27
1.55
1.84
2.13
2.88
3.45
4.60
5.75
6.90
8.05
9.20
Define the circuit’s operating parameters.
Select the PolySwitch RUE device that will accommodate the
circuit’s maximum ambient operating temperature and
normal operating current.
20°
0.90
1.10
1.35
1.60
1.85
2.50
3.00
4.00
5.00
6.00
7.00
8.00
9.00
40°
0.75
0.91
1.12
1.33
1.54
2.08
2.49
3.32
4.15
4.98
5.81
6.64
7.47
50°
0.69
0.85
1.04
1.23
1.42
1.93
2.31
3.08
3.85
4.62
5.39
6.16
6.93
60°
0.61
0.75
0.92
1.09
1.26
1.70
2.04
2.72
3.40
4.08
4.76
5.44
6.12
Raychem Circuit Protection Devices
_______________
_______________
_______________
_______________
70°
0.55
0.67
0.82
0.98
1.13
1.53
1.83
2.44
3.05
3.66
4.27
4.88
5.49
85°
0.47
0.57
0.70
0.83
0.96
1.30
1.56
2.08
2.60
3.12
3.64
4.16
4.68

Related parts for RUExxx