AD8314 Analog Devices, AD8314 Datasheet - Page 19

no-image

AD8314

Manufacturer Part Number
AD8314
Description
100 MHz to 2.7 GHz, 45 dB RF Detector/Controller
Manufacturer
Analog Devices
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD8314
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD8314ACP
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD8314ACP-REEL
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD8314ACP-REEL7
Manufacturer:
NEC
Quantity:
2 122
Part Number:
AD8314ACP-REEL7
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD8314ACPZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD8314ARM
Manufacturer:
AD
Quantity:
5 321
Part Number:
AD8314ARM
Manufacturer:
AD
Quantity:
195
Part Number:
AD8314ARM
Manufacturer:
ADI
Quantity:
77
Part Number:
AD8314ARM-REEL7
Manufacturer:
AD
Quantity:
5 379
Part Number:
AD8314ARMZ
Manufacturer:
ADI
Quantity:
3
Company:
Part Number:
AD8314ARMZ-REEL
Quantity:
3 000
Table 7. Evaluation Board Configuration Options
Component
TP1, TP2
SW1
R1, R2
R3, R4, C2,
R5, R6, C3
C1, R9
C4
R7, R8
LK1
Figure 46. Layout of Component Side (MSOP)
Function
Supply and Ground Vector Pins.
Device Enable: When in Position A, the ENBL pin is connected to +V
operating mode. In Position B, the ENBL pin is grounded, putting the device in power-down mode.
Input Interface. The 52.3 Ω resistor in Position R2 combines with the AD8314’s internal input
impedance to give a broadband input impedance of around 50 Ω. A reactive match can be
implemented by replacing R2 with an inductor and R1 (0 Ω) with a capacitor. Note that the
AD8314’s RF input is internally ac-coupled.
Output Interface. R4, C2, R6, and C3 can be used to check the response of V_UP and V_DN to
capacitive and resistive loading. R3/R4 and R5/R6 can be used to reduce the slope of V_UP
and V_DN.
Power Supply Decoupling. The nominal supply decoupling consists of a 0.1 μF capacitor (C1).
A series inductor or small resistor can be placed in R9 for additional decoupling.
Filter Capacitor. The response time of V_UP and V_DN can be modified by placing a capacitor
between FILTR and V_UP.
Slope Adjust. By installing resistors in R7 and R8, the nominal slope of 20 mV/dB can be
increased. See Increasing the Logarithmic Slope in Measurement Mode for more details.
Measurement/Controller Mode. LK1 shorts V_UP to VSET, placing the AD8314 in measurement
mode. Removing LK1 places the AD8314 in controller mode.
Rev. B | Page 19 of 20
S
and the AD8314 is in
Figure 47. Silkscreen of Component Side (MSOP)
Default Condition
Not Applicable
SW1 = A
R2 = 52.3 Ω (Size 0603)
R1 = 0 Ω (Size 0402)
R4 = C2 = R6 =
C3 = Open (Size 0603)
R3= R5 = 0 Ω (Size 0603)
C1 = 0.1 μF (Size 0603)
R9 = 0 Ω (Size 0603)
C4 = Open (Size 0603)
R7 = 0 Ω (Size 0603)
R8 = Open (Size 0603)
LK1 = Installed
AD8314