7. RELIABILITY TEST CONDITIONS
7.1 Temperature and Humidity
7.3 Electrostatic Discharge
7.4 Judgment standard
7.2 Shock & Vibration
[NOTE] Measure point :(1) LCD glass and metal bezel
The judgment of the above test should be made as follow:
Pass: Normal display image with no obvious non-uniformity and no line defect.
Fail: No display image, obvious non-uniformity, or line defects.
TEST ITEM
Thermal Shock (No operation)
High Temperature Operation
(Non-Operation)
(Non-Operation)
Low Temperature Operation
High Temperature Storage
Low Temperature Storage
ESD
High Humidity Operation
Vibration
(Partial transformation of the module parts should be ignored.)
ITEMS
Shock
High Temperature
TEST ITEMS
(2) IF connector pins
150pF,330Ω,±8kV&±15kV air & contact test
980m/S^2(equal to 100G), 6ms,
(1/2 Sine wave),
Each axis X,Y,Z.
Frequency range:8~33.3Hz
Stoke:1.3 mm
Vibration: sinusoidal wave, perpendicular axis(both x,z axis: 2Hrs ,
Sweep: 2.9G, 33.3~400Hz
Cycle: 15 min
y axis: 4Hrs).
15/15
200pF,0Ω,±200V contact test
CONDITIONS
-30℃; 240hrs (Backlight unit always turn on)
60℃; 90%RH; 240hrs (No condensation)
SPEC_CLAA090JB02CW_V0.1_STUDIO_070719
Between –30℃(0.5hr) and 85℃(0.5hr);
www.DataSheet.net/
CONDITIONS
CHUNGHWA PICTURE TUBES, LTD.,
CONDITIONS
-40℃; 240hrs
85℃; 240hrs
95℃; 240hrs
200 Cycles
Note
(1)
(2)
www.yslcd.com.tw
Datasheet pdf - http://www.DataSheet4U.co.kr/

Related parts for CLAA090JB02CW