SKY73100 Skyworks Solutions, SKY73100 Datasheet - Page 7

no-image

SKY73100

Manufacturer Part Number
SKY73100
Description
High Performance VCO/Synthesizer
Manufacturer
Skyworks Solutions
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SKY73100
Manufacturer:
Triquint
Quantity:
1 400
Part Number:
SKY73100
Manufacturer:
SKYWORKS/思佳讯
Quantity:
20 000
Part Number:
SKY73100-11
Manufacturer:
Skyworks
Quantity:
1 400
tape and reel format. For packaging details, refer to the Skyworks
Application Note, Tape and Reel, document number 101568.
Circuit Design Considerations
The following design considerations are general in nature and
must be followed regardless of final use or configuration
1. Paths to ground should be made as short and as low
2. The ground pad of the SKY73100 provides critical electrical
3. Skyworks recommends including external bypass capacitors
4. A 50 Ω impedance trace is needed for the RF_OUT (pin 10)
Table 3. SKY73100 Absolute Maximum Ratings (Note 1)
Table 4. SKY73100 Recommended Operating Conditions
Note 1: Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other
www.DataSheet4U.com
Supply voltage
Operating temperature, full performance
Storage temperature
Supply voltage
Input voltage (CLK, DATA, LE):
Output voltage (LD) with 18 k Ω load from
VCC PLL:
Reference frequency input voltage (FREF,
pin 23)
Load connected to RF output
RF output switch enable:
impedance as possible.
grounding requirements. Design the connection to the ground
pad to provide the best electrical connection to the circuit
board. Multiple vias to the grounding layer are recommended
to connect the top layer ground area to the main ground layer.
on the VDD voltage input (pin 37) of the device. These
capacitors should be placed as close as possible to the VDD
input pin.
line.
Low level
High level
Low level, unlocked
High level, unlocked
High
Low
parameters set at or below their nominal values.
200361A • Skyworks Proprietary and Confidential Information • Products and Product Information are Subject to Change Without Notice • June 20, 2007
Parameter
Parameter
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
VCC
T
T
VCC
FREF
SWEN
SWEN
OP
ST
IN
H
L
Symbol
Symbol
4.75
Min
–40
–40
Min
1.4
2.4
0.5
2.2
0
Electrical and Mechanical Specifications
The absolute maximum ratings of the SKY73100 are provided in
Table 3. The recommended operating conditions are specified in
Table 4 and electrical specifications are provided in Table 5. Spur
suppression measurements are provided in Table 6.
Measurement plots for single sideband phase noise and settling
time are shown in Figures 5 and 6, respectively.
A typical application schematic for the SKY73100 is provided in
Figure 7. Figure 8 shows the package dimensions for the 38-pin
MCM and Figure 9 provides the tape and reel dimensions.
Electrostatic Discharge (ESD) Sensitivity
The SKY73100 ESD threshold level is 2500 VDC using Human
Body Model (HBM) testing. This level applies to RF signal lines
>100 MHz, analog and RF lines <100 MHz, digital lines, power
supply lines, and ground pins.
To avoid latent or visible ESD damage, always follow proper ESD
handling precautions.
50 Ω , maximum VSWR (load input) 2.0:1, all phases
PRELIMINARY DATA SHEET • SKY73100 VCO/SYNTHESIZER
Typical
Typical
5.00
1.0
+150
Max
Max
5.25
+85
5.5
0.6
0.4
1.5
0.8
Units
Units
Vp-p
°C
°C
V
V
V
V
V
V
V
V