BFP92 Vishay Telefunken, BFP92 Datasheet

no-image

BFP92

Manufacturer Part Number
BFP92
Description
Silicon NPN Planar RF Transistor
Manufacturer
Vishay Telefunken
Datasheet
Silicon NPN Planar RF Transistor
Applications
RF amplifier up to GHz range, especially for wide band
antenna amplifiers.
Features
BFP92A Marking: 92V
Plastic case (SOT 143)
1 = Collector, 2 = Emitter, 3 = Base, 4 = Emitter
Absolute Maximum Ratings
T
Maximum Thermal Resistance
T
Collector-base voltage
Collector-emitter voltage
Emitter-base voltage
Collector current
Total power dissipation
Junction temperature
Storage temperature range
Junction ambient on glass fibre printed board (25 x 20 x 1.5) mm
Document Number 85019
Rev. 3, 20-Jan-99
D
D
D
amb
amb
2
3
High power gain
Low noise figure
High transition frequency
Parameter
= 25
= 25
94 9279
_
_
1
C, unless otherwise specified
C, unless otherwise specified
4
Parameter
plated with 35
m
m Cu
Test Conditions
13 579
Test Conditions
T
amb
60 ° C
BFP92AW Marking: W92
Plastic case (SOT 343)
1 = Collector, 2 = Emitter, 3 = Base, 4 = Emitter
Electrostatic sensitive device.
Observe precautions for handling.
2
3
1
4
3
13 653
BFP92A/BFP92AW
www.vishay.de FaxBack +1-408-970-5600
Symbol
Symbol
R
V
V
V
thJA
T
P
CBO
CEO
EBO
I
T
stg
C
tot
j
Vishay Telefunken
–65 to +150
Value
450
Value
200
150
20
15
30
2
13 566
Unit
mW
Unit
K/W
mA
° C
° C
V
V
V
1 (10)

Related parts for BFP92

BFP92 Summary of contents

Page 1

... Features D High power gain D Low noise figure D High transition frequency 9279 3 4 BFP92A Marking: 92V Plastic case (SOT 143 Collector Emitter Base Emitter Absolute Maximum Ratings unless otherwise specified amb Parameter Collector-base voltage Collector-emitter voltage Emitter-base voltage ...

Page 2

... BFP92A/BFP92AW Vishay Telefunken Electrical DC Characteristics = unless otherwise specified T amb Parameter Collector cut-off current Collector-base cut-off current Emitter-base cut-off current Collector-emitter breakdown voltage I Collector-emitter saturation voltage DC forward current transfer ratio Electrical AC Characteristics = unless otherwise specified T amb Parameter Transition frequency V CE ...

Page 3

... Document Number 85019 Rev. 3, 20-Jan-99 BFP92A/BFP92AW S11 S21 LIN LIN ANG ANG MAG MAG deg deg –16.8 6.54 165.6 0.019 –47.3 5.72 142.2 0.049 –72.7 4.83 124 ...

Page 4

... BFP92A/BFP92AW Vishay Telefunken LIN /mA f/MHz CE C MAG 100 0.561 300 0.431 500 0.398 800 0.391 1000 0.392 1200 0.401 14 1500 0.423 1800 0.440 2000 0.455 2200 0.478 2500 0.499 2800 0.533 3000 0.546 100 0.478 300 0.411 500 0.402 800 0 ...

Page 5

... Document Number 85019 Rev. 3, 20-Jan-99 BFP92A/BFP92AW S11 S21 LIN LIN ANG ANG MAG MAG deg deg –15.8 6.53 166.1 0.015 –45.0 5.76 143.2 0.041 –69.6 4.87 125 ...

Page 6

... BFP92A/BFP92AW Vishay Telefunken LIN /mA f/MHz CE C MAG 100 0.605 300 0.436 500 0.381 800 0.364 1000 0.363 1200 0.370 14 1500 0.393 1800 0.412 2000 0.424 2200 0.448 2500 0.474 2800 0.502 3000 0.522 100 0.535 300 0.406 500 0.379 800 0 ...

Page 7

... V 12878 Figure 3. Collector Base Capacitance vs f=800MHz 12879 Figure 4. Noise Figure vs. Collector Current BFP92A/BFP92AW Vishay Telefunken – Collector Base Voltage ( Collector Base Voltage =10V W = – Collector Current ( www.vishay.de FaxBack +1-408-970-5600 ...

Page 8

... BFP92A/BFP92AW Vishay Telefunken j0.5 3.0 GHz j0.2 2 1.0 –j0.2 0.1 0.3 –j0.5 12 986 –j Figure 5. Input reflection coefficient 120 0.3 0.1 0.5 1.0 180 10 3.0 GHz –150 –120 –90 12 988 Figure 6. Forward transmission coefficient www.vishay.de FaxBack +1-408-970-5600 8 (10 120 j2 150 180 – ...

Page 9

... Dimensions of BFP92A in mm Dimensions of BFP92AW in mm Document Number 85019 Rev. 3, 20-Jan-99 BFP92A/BFP92AW Vishay Telefunken 96 12240 96 12237 www.vishay.de FaxBack +1-408-970-5600 9 (10) ...

Page 10

... BFP92A/BFP92AW Vishay Telefunken Ozone Depleting Substances Policy Statement It is the policy of Vishay Semiconductor GmbH to 1. Meet all present and future national and international statutory requirements. 2. Regularly and continuously improve the performance of our products, processes, distribution and operating systems with respect to their impact on the health and safety of our employees and the public, as well as their impact on the environment ...

Related keywords