LT10000-S LEM, LT10000-S Datasheet

no-image

LT10000-S

Manufacturer Part Number
LT10000-S
Description
Current Transducer LT 10000-S
Manufacturer
LEM
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
LT10000-S
Quantity:
1 000
Current Transducer LT 10000-S
For the electronic measurement of currents : DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
I
I
R
I
K
V
I
V
X
I
I
t
di/dt
f
T
T
R
m
Notes :
LEM Components
PN
P
SN
C
OT
O
r
C
A
S
d
M
N
G
L
S
Electrical data
Accuracy - Dynamic performance data
General data
Primary nominal r.m.s. current
Primary current, measuring range (1 s / mn)
Measuring resistance
Secondary nominal r.m.s. current
Conversion ratio
Supply voltage (± 5 %)
Current consumption
R.m.s. voltage for AC isolation test, 50 Hz, 1 mn
Overall accuracy @ I
Linearity
Offset current @ I
Thermal drift of I
Response time
di/dt accurately followed
Frequency bandwidth (- 1 dB)
Ambient operating temperature
Ambient storage temperature
Secondary coil resistance @ T
Mass
Standards
1)
2)
3)
4)
Between primary and secondary + shield
Between secondary and shield
With a di/dt of 100 A/µs
A list of corresponding tests is available
with ± 48 V
with ± 60 V
4)
3)
O
@ 90 % of I
P
= 0, T
PN
, T
A
A
= 25°C
@ ± 10000 A
@ ± 12000 A
@ ± 10000 A
@ ± 15000 A
= 25°C
P max
A
= 70°C
- 25°C .. + 70°C
max
max
max
max
10000
0 .. ± 15000
R
1
1 : 10000
± 48 .. 60
40
10
1
± 0.3
< 0.1
< 1
> 50
DC .. 100
- 25 .. + 70
- 40 .. + 85
35
17
EN 50178
± 0.6
0
0
0
0
Typ
M min
2)
(@ ± 60 V) +
1)
± 1.5
± 0.8
Max
1.5
R
20
8
1
M max
I
S
A/µs
kHz
mA
mA
mA
kV
kV
µs
°C
°C
kg
%
%
A
A
A
V
I
Features
Advantages
Applications
PN
Closed loop (compensated) current
transducer using the Hall effect
Insulated case.
Excellent accuracy
Very good linearity
Low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
Current overload capability.
AC variable speed drives and servo
motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies
(UPS)
Switched Mode Power Supplies
(SMPS)
Power supplies for welding
applications.
=
10000 A
w w w .lem.com
980708/6

Related parts for LT10000-S

LT10000-S Summary of contents

Page 1

... Current overload capability. % Applications % AC variable speed drives and servo mA motor drives mA Static converters for DC motor drives µs Battery supplied applications A/µs Uninterruptible Power Supplies kHz (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. °C °C kg 980708 .lem.com ...

Page 2

... Terminal E : shield Mechanical characteristics General tolerance Fastening Primary through-hole Connection of secondary Fastening torque LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. (in mm 0.0394 inch) Remarks ± positive when holes 11 mm ...