LTC1710 Linear Technology, LTC1710 Datasheet
![no-image](/images/manufacturer_photos/0/3/388/linear_technology_sml.jpg)
LTC1710
Available stocks
Related parts for LTC1710
LTC1710 Summary of contents
Page 1
... The LTC1710 has one three-state programmable address pin that allows three different addresses for a total of six available switches on the same bus. The LTC1710 also features a separate user-controlled drain supply (SW0D) to Switch 0 so that it can be used to control SMBus peripherials using a different power supply ...
Page 2
... OSC (Note RATINGS Operating Temperature Range LTC1710C................................................ LTC1710I ............................................ – Junction Temperature** ...................................... 125 C + 0.3V Storage Temperature Range .................. – 150 C CC Lead Temperature (Soldering, 10 sec)................... 300 C *Supply rails to DATA and CLK are independent of V **Although the LTC1710 can sustain T ...
Page 3
... Note 4: The oscillator frequency is not tested directly but is inferred from turn-on time. Note 5: SMBus timing specifications are guaranteed but not tested. Note enabled upon receiving the Stop condition from the SMBus master. Note 7: OFF is enabled upon receiving the Stop condition from the SMBus master. LTC1710 MIN TYP MAX ) 200 CC ...
Page 4
... LTC1710 W U TYPICAL PERFOR A CE CHARACTERISTICS Standby Current vs Temperature 3. 2. – 100 0 TEMPERATURE ( C) 1710 G01 Switch R vs Temperature DS(ON) (SO-8 Package) 1 300mA OUT 0.9 0.8 0 2. 3. 0.4 CC 0.3 0.2 0.1 0 – 100 TEMPERATURE ( C) 1710 G04 PIN FUNCTIONS SW0D (Pin 1): Drain Supply of Switch 0. User-program- mable from ...
Page 5
... SU:DAT HD:DAT The protocol that the LTC1710 uses is the Send Byte Pro- tocol. In this protocol, the master first sends out a Start signal by switching the DATA line from high to low while CLK is high. (Because there may be more than one master on the same bus, an arbitration process takes place if two masters attempt to take control of the DATA line simulta- neously ...
Page 6
... LTC1710, even if the address sent by the master matches that of the LTC1710. After reception of the first byte, the slave device (LTC1710) with the matching address then acknowledges the master by pulling the DATA line low before the next rising clock edge ...
Page 7
... The LTC1710 starts up with both gate drives low. An internal power-on reset (POR) signal inhibits operation U TYPICAL APPLICATIONS The LTC1710, when used with the LT switch a regulated 3.3V/300mA supply to a load (Figure 3). Also, with the help of the LT1304-5, the LTC1710 can ...
Page 8
... SMBus Dual High Side Switch Controller PowerPath is a trademark of Linear Technology Corporation. Linear Technology Corporation 8 1630 McCarthy Blvd., Milpitas, CA 95035-7417 (408) 432-1900 FAX: (408) 434-0507 www.linear-tech.com 3. SW0D CLK OUT0 LTC1710 6 DATA AD1 OUT1 100 F 3 GND 499k SENSE ...