dms-ps-cm Murata Manufacturing Co., Ltd, dms-ps-cm Datasheet
dms-ps-cm
Related parts for dms-ps-cm
dms-ps-cm Summary of contents
Page 1
... Watts---that’s nearly seven times less than a standard 4W F1 AC/DC Converter Drive Circuitry Figure 1. Simplified Schematic Figure 1. DMS-PS-CM Series Simplified Schematic www.murata-ps.com DMS-PS-CM Series C US E156931 ® night light! These low cost, high-efficiency power supplies can signifi ...
Page 2
... Free air convection with derating (see Figure 3 and Technical 0 to 85% See Mechanical Specifications 5.8 ounces (165 grams) 6.9 ounces (195 grams) 7.9 ounces (223 grams) ABS, UL94 5VA Phenolic, UL94 V-0 Plastic, UL94 V-1 Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000 MPM_DMS-PS-CM.B02 Page ...
Page 3
... AC Supply Fuse (F1): All DMS-PS-CM Series power supplies are equipped with a built-in 1A/250V time-lag fuse. Replacement fuses must be of the same type and rating; please refer to the Functional Specifications section of this datasheet for more information ...
Page 4
... Unless forced air with the velocity noted above is employed, DMS-PS-CM supplies should never be mounted upside down (terminal blocks facing down). Also, always provide sufficient clearances in order to ensure adequate airfl ...
Page 5
... Application Information 1. Chassis Mounting Considerations: In order to minimize self-heating, DMS-PS-CM power supplies should always be mounted in either a vertical or horizontal position. Avoid mounting units upside-down or in close proximity to other heat-generating devices. Also, be sure to use the mounting hardware described in Figure 4 below in order to ensure a secure, vibration-resistant installation. ...
Page 6
... High Efficiency, AC/DC Instrumentation Power Supplies with Individually Isolated Outputs = +25° 120V @60Hz IN Noise and Ripple - 100% Load, 20MHz Bandwidth DMS-PS6-CM V1 (+24V) DMS-PS6-CM V2 (+4.85V) www.murata-ps.com DMS-PS-CM Series DMS-PS9-CM V1 (+24V) DMS-PS9-CM V2 (+4.85V) Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000 MPM_DMS-PS-CM.B02 Page ...
Page 7
... High Efficiency, AC/DC Instrumentation Power Supplies with Individually Isolated Outputs = +25° 120V @60Hz IN Transient Response - 10% to 100% Load Step DMS-PS6-CM V1 (+24V) DMS-PS6-CM V2 (+4.85V) www.murata-ps.com DMS-PS-CM Series DMS-PS9-CM V1 (+24V) DMS-PS9-CM V2 (+4.85V) Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000 MPM_DMS-PS-CM.B02 Page ...
Page 8
... Osaka, Tel: 6-6354-2025, email: sales_osaka@murata-ps.com Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com Parkway Centre, Tel: +65 6348 9096, email: singapore@murata-ps.com Technical enquiries email: sales@murata-ps.com, tel: MPM_DMS-PS-CM.B02 Page 2.835 (72.0) +1 508 339 3000 ...