a120urd73li0800 AEGIS SEMICONDUTORES LTDA, a120urd73li0800 Datasheet

no-image

a120urd73li0800

Manufacturer Part Number
a120urd73li0800
Description
Semiconductor Protection Fuses
Manufacturer
AEGIS SEMICONDUTORES LTDA
Datasheet
®
®
®
®
®
PSC SQUARE BODY
1250/1300 Volt
Part Number Designation:
1 1 2 2 , , 5 5 U U R R D D : :
A A 1 1 3 3 0 0 U U R R D D : :
*V n = rated voltage
HIGHLIGHTS:
®
®
Ratings
Extremely Fast Acting
Current Limiting
Very Low I
Worldwide Acceptability
Superior Cycling Ability
AC: 50-1800A
DC: Consult Factory
650-1300 VAC
100 kA IR
2
t
European/IEC
Mounting Style/Approval
Tested @ 1.1 V n
North American
Mounting Style/Approval
Tested @ V n
®
Approvals
®
®
APPLICATIONS:
Protection of rectifiers,
inverters, DC drives, UPS
Systems, reduced voltage
motor starters, and other
equipment in globally
accepted applications
UL Recognized
Component
Sizes 70,71,72,73
tested to IEC 269.4
SEMICONDUCTOR PROTECTION FUSES
North American Reference Numbering System
A.C.
Rated Volts
(130=1300V)
Class
Size
Mounting Types
Straight-blade
Straight-blade
Flat-type, one hole (American)
Indicator
Amp Rating
D 75
Ferraz Shawmut 1250/1300V PSC fuse-links provide maximum
flexibility in equipment design and ultimate protection for today’s
power conversion equipment. These square body fuse-links are
available in four different body sizes, each size having four world-
wide acceptable mounting styles. The different mounting styles
and body sizes along with a broad range of ampere ratings allow
greatest flexibility in equipment design.
The Ferraz Shawmut PSC fuses have been engineered to provide
state-of-the-art protection for SCR’s, diodes, thyristors, GTO’s
and IGBT devices. They have pure silver die-cut elements
embedded in solidified sand which helps control arcing charac-
teristics for low I
surfaces are silver plated and all hardware is non-magnetic.
All fuse links are equipped with a low voltage trip-indicator. This
trip-indicator can operate a field mountable microswitch which is
easily mounted directly onto the fuse even while in service.
®
®
®
*For Microswitch information see page J10
Features / Benefits
70
71
72
73
LI
LLI
TTI
A 130 URD 71
Choice of mounting styles gives wide choice for
equipment design
Broad range of ampere ratings in a given body
size for design flexibility
IEC 269-4 compliance for fuses for worldwide
semiconductor applications
2
t and high interrupting rating. All contact
I 350
European / IEC Reference Numbering System
Rated Volts
(12,5=1250V)
Class
Size
Mounting Types
DIN 110
Flat-type, one hole (metric)
Indicator
Amp Rating
70
71
72
73
D11A
TTF
12,5 URD 71
I 350
D

Related parts for a120urd73li0800

a120urd73li0800 Summary of contents

Page 1

PSC SQUARE BODY 1250/1300 Volt HIGHLIGHTS: APPLICATIONS: Extremely Fast Acting Protection of rectifiers, ® ® inverters, DC drives, UPS ® Current Limiting Systems, reduced voltage Very Low ® motor starters, and other Worldwide Acceptability ® equipment in ...

Page 2

PSC SQUARE BODY 1250/1300 Volt Outline Dimensions Type D11A 10 Types LI and LLI 72.5 MAX (2.85 ...

Page 3

PSC SQUARE BODY 1250/1300 Volt Types TTI and TTF 5.03 A (.20) 72.5 MAX (2.85) 74 (2.91) SIZE REF. AND DIMENSION PER PAIR OF STUDS 70 & 801 ( & M ...

Page 4

PSC SQUARE BODY 1250/1300 Volt 1250 Volt European/IEC Style Ratings and Application Data Body Amp Rated Size Rating Voltage (A 50 1250 63 1250 80 1250 100 1250 125 1250 160 1250 70 200 1250 250 1250 280 1200 280 ...

Page 5

... A130URD73LI0450 44 390 110/112 A130URD73LI0500 57 500 116/120 A130URD73LI0550 84 730 125/132 A130URD73LI0630 110 960 135/146 A130URD73LI0700 190 1630 136 A120URD73LI0800 190 1630 148 - 250 2160 150 A110URD73LI0900 250 2160 170 - 370 2430 152/174 A100URD73LI1000 445 2580 168/208 A100URD73LI1100 585 3480 186/200 ...

Page 6

PSC SQUARE BODY 1250/1300 Volt Melting Time – Current Data Current in Amperes Melting Time – Current Data Current in Amperes SEMICONDUCTOR PROTECTION FUSES A130 URD 70 & 12,5 URD 350A Available Current in RMS Symmetrical Amperes ...

Page 7

PSC SQUARE BODY 1250/1300 Volt A130 URD 72 & 12,5 URD 72 Melting Time – Current Data Current in Amperes A130 URD 73 & 12,5 URD 73 Melting Time – Current Data Current in Amperes SEMICONDUCTOR PROTECTION FUSES 280 to ...

Page 8

PSC SQUARE BODY 1250/1300VAC Clearing I2t vs. Operating Voltage Operating Voltage Watts Loss vs. Rated Current % Rating Correction factor to determine watts loss value of a fuse operating below its rated current. SEMICONDUCTOR PROTECTION FUSES Maximum Arc Voltage vs. ...

Page 9

PSC SQUARE BODY 1250/1300Volt DC Voltage Capability vs. Time Constant DC Voltage Capabilities DC Working Voltage Provides the DC voltage capability of a fuse as a function of circuit time constant (L/R ...

Page 10

PSC SQUARE BODY 1250/1300Volt SIZE CATALOG NO. 12,5 URD 73 PPAF 0315 12,5 URD 73 PPAF 0350 12,5 URD 73 PPAF 0400 12,5 URD 73 PPAF 0450 12,5 URD 73 PPAF 0500 12,5 URD 73 PPAF 0550 12,5 URD 73 ...

Page 11

PSC SQUARE BODY 1250/1300 2X72 Melting Time Current Data Current in Amperes SEMICONDUCTOR PROTECTION FUSES Peak let thru Current Data Available Current in RMS Symmetrical Amperes Time-current characteristics Above, left: Curves indicating pre-arcing time for each rated current as a ...

Page 12

PSC SQUARE BODY 1250/1300 2x73 Melting Time Current Data Current in Amperes Clearing Data Current in Amperes SEMICONDUCTOR PROTECTION FUSES Peak let thru Current Data Available Current in RMS Symmetrical Amperes Time-current characteristics Above, left: Curves indicating ...