upd63a Renesas Electronics Corporation., upd63a Datasheet - Page 12

no-image

upd63a

Manufacturer Part Number
upd63a
Description
4-bit Single-chip Microcontroller For Infrared Remote Control Transmission
Manufacturer
Renesas Electronics Corporation.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
upd63aGS-401
Manufacturer:
NEC
Quantity:
5 000
Part Number:
upd63aGS-401
Manufacturer:
NEC
Quantity:
5 000
Part Number:
upd63aGS-402
Manufacturer:
NEC
Quantity:
400
Part Number:
upd63aGS-402
Manufacturer:
NEC
Quantity:
1 000
Part Number:
upd63aGS-403
Manufacturer:
NEC
Quantity:
1 000
Part Number:
upd63aGS-406
Manufacturer:
NEC
Quantity:
1 000
Part Number:
upd63aGS-413
Manufacturer:
NEC
Quantity:
1 000
Part Number:
upd63aGS-417
Manufacturer:
NEC
Quantity:
95
Part Number:
upd63aGS-422
Manufacturer:
NEC
Quantity:
3 148
Part Number:
upd63aGS-425
Manufacturer:
NEC
Quantity:
20 000
Part Number:
upd63aGS-445-T1
Manufacturer:
SHARP
Quantity:
200
Part Number:
upd63aGS-445-TI
Manufacturer:
NEC
Quantity:
20 000
2.8 Arithmetic and Logic Unit (ALU): 4 Bits
manipulations with priority given to logical operations.
2.9 Flags
2.9.1 Status flag (F)
12
Operand Value of STTS Instruction
The arithmetic and logic unit (ALU), which refers to an arithmetic circuit consisting of 4 bits, executes simple
Pin and timer statuses can be checked by executing the STTS instruction to check the status flag.
The status flag is set (to 1) in the following cases.
• If the condition specified with the operand is met when the STTS instruction has been executed
• When STANDBY mode is canceled.
• When the cancelation condition is met at the point of executing the HALT instruction. (In this case, the system
Conversely, the status flag is cleared (to 0) in the following cases:
• If the condition specified with the operand is not met when the STTS instruction has been executed.
• When the status flag has been set (to 1), the HALT instruction executed, but the cancelation condition is not
b
0
1
3
is not placed in STANDBY mode.)
met at the point of executing the HALT instruction. (In this case, the system is not placed in STANDBY mode.)
Either of the combinations
of b
b
0
0
1
1
2
2
, b
1
, and b
Table 2-1. Conditions for Status Flag (F) to be Set by STTS Instruction
b
0
1
1
0
1
0
above.
b
0
1
0
1
0
High level is input to at least one of K
High level is input to at least one of K
High level is input to at least one of K
The down counter of the timer is 0.
High level is input to at least one of S
[The following condition is added in addition to the above.]
Condition for Status Flag (F) to be Set
I
I
I
0
pins.
pins.
pins.
and S
1
pins.
PD63, 63A, 64

Related parts for upd63a