ENTRANCE SLIT
TG series mini-spectrometers use a transmission holographic
grating made of quartz and precision optical components
arranged on a rugged optical base, making it possible to
deliver high throughput and highly accurate optical charac-
teristics.
Installing the dedicated software package (containing sample software, device driver, DLL)*
following basic tasks:
· Measurement data acquisition and save
· Measurement condition setup
· Module information acquisition
· Graphic display
· Arithmetic operation
Note: Two or more mini-spectrometers can be
*13: Compatible OS: Microsoft Windows
Device driver and DLL for controlling hardware are also provided.
You can develop your own measurement programs by using a software development environment that includes Microsoft Visual
C++ and Visual Basic.*
data and module information acquisition.
*14: Operation of the device driver and DLL has been verified only with Microsoft Visual C++
(wavelength conversion factor, polychromator type, etc.)
Optical component layout
Dedicated software package (supplied with unit)
Pixel number to wavelength conversion
Dark subtraction
Comparison calculation with reference data
(transmittance, reflectance)
Gaussian approximation
(peak position and count, FWHM)
COLLIMATING LENS
Microsoft Visual C++ and Microsoft Visual Basic are either registerd trademarks or trademarks of Microsoft Corporation in the
United States.
Professional Edition 2000
(SP3 or later) and XP (SP1a or later)
connected and used with one PC
simultaneously.
TRANSMISSION GRATING
Mini-spectrometer TG series
FOCUSING LENS
14
The DLL provides functions such as USB port open/close, measurement condition setup, measurement
IMAGE SENSOR
KACCC0256EA
C9406GC, C9913GC, C9914GB
(Deuterium lamp and Halogen lamp)
UV-VIS FIBER LIGHT SOURCE
(transmission light measurement)
Light to be measured is guided into the entrance port of TG
series through an optical fiber and the spectrum measured
with the built-in image sensor is output through the USB port
to a PC for data acquisition. There are no moving parts inside
the unit so stable measurements are obtained at all times. An
optical fiber that guides light input from external sources al-
lows a flexible measurement setup.
Connection example
L10290
* External power supply should be prepared by the user.
C9406GC: No external power supply required (Uses USB bus power)
FIBER
MINI-SPECTROMETER
C9913GC, C9914GB
USB CABLE
®
13
QUARTZ CELL (For holding liquid sample)
and Visual Basic
into your PC allows running the
PC
POWER SUPPLY FOR
COOLING ELEMENT AND
COOLING FAN *
®
.
KACCC0370EA