st72f321r STMicroelectronics, st72f321r Datasheet - Page 62

no-image

st72f321r

Manufacturer Part Number
st72f321r
Description
64/44-pin 8-bit Mcu With 32 To 60k Flash/rom, Adc, Five Timers, Spi, Sci, I2c Interface
Manufacturer
STMicroelectronics
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
st72f321r6-AUTO
Manufacturer:
ST
0
Part Number:
st72f321r6T6
Manufacturer:
BROADCOM
Quantity:
201
Part Number:
st72f321r6T6
Manufacturer:
STMicroelectronics
Quantity:
10 000
Part Number:
st72f321r6T6
Manufacturer:
ST
Quantity:
20 000
Part Number:
st72f321r6T6TR
Manufacturer:
STMicroelectronics
Quantity:
10 000
Part Number:
st72f321r6TA
Manufacturer:
ST
Quantity:
370
Part Number:
st72f321r6TA
Manufacturer:
STMicroelectronics
Quantity:
10 000
Part Number:
st72f321r6TA
Manufacturer:
ST
0
Part Number:
st72f321r9T6
Manufacturer:
ST
Quantity:
465
Part Number:
st72f321r9T6
Manufacturer:
ST
Quantity:
20 000
ST72321
PWM AUTO-RELOAD TIMER (Cont’d)
Independent PWM signal generation
This mode allows up to four Pulse Width Modulat-
ed signals to be generated on the PWMx output
pins with minimum core processing overhead.
This function is stopped during HALT mode.
Each PWMx output signal can be selected inde-
pendently using the corresponding OEx bit in the
PWM Control register (PWMCR). When this bit is
set, the corresponding I/O pin is configured as out-
put push-pull alternate function.
The PWM signals all have the same frequency
which is controlled by the counter period and the
ARTARR register value.
When a counter overflow occurs, the PWMx pin
level is changed depending on the corresponding
OPx (output polarity) bit in the PWMCR register.
Figure 39. PWM Auto-reload Timer Function
Figure 40. PWM Signal from 0% to 100% Duty Cycle
62/189
AUTO-RELOAD
DUTY CYCLE
f
(PWMDCRx)
PWM
WITH OEx=1
AND OPx=0
WITH OEx=1
AND OPx=1
REGISTER
REGISTER
(ARTARR)
= f
OCRx=FCh
OCRx=FDh
OCRx=FEh
OCRx=FFh
COUNTER
f
COUNTER
COUNTER
255
000
/ (256 - ARTARR)
FDh
FEh
ARTARR=FDh
FFh
FDh
When the counter reaches the value contained in
one of the output compare register (OCRx) the
corresponding PWMx pin level is restored.
It should be noted that the reload values will also
affect the value and the resolution of the duty cycle
of the PWM output signal. To obtain a signal on a
PWMx pin, the contents of the OCRx register must
be greater than the contents of the ARTARR reg-
ister.
The maximum available resolution for the PWMx
duty cycle is:
Note: To get the maximum resolution (1/256), the
ARTARR register must be 0. With this maximum
resolution, 0% and 100% can be obtained by
changing the polarity.
FEh
Resolution = 1 / (256 - ARTARR)
FFh
FDh
FEh
t
t