mmdoe28gxmsp-0va Samsung Semiconductor, Inc., mmdoe28gxmsp-0va Datasheet - Page 26

no-image

mmdoe28gxmsp-0va

Manufacturer Part Number
mmdoe28gxmsp-0va
Description
Samsung Pm410 Ssd 1.8 Lif 128/64gb
Manufacturer
Samsung Semiconductor, Inc.
Datasheet
7.3.2.3 Off-Line Data Collection Status
The value of this byte defines the current status of the off-line activities of the device. Bit 7 indicates an Automatic Off-line Data Collection Sta-
tus.
Bit 7 Automatic Off-line Data Collection Status
0
1
Bits 0–6 represent a hexadecimal status value reported by the device.
Value
7.3.2.4 Self-test execution status
Bit
0-3
4-7
7.3.2.5 Total time in seconds to complete off-line data collection activity
This field tells the host how many seconds the device requires to complete the off-line data collection activity.
7.3.2.6 Current segment pointer
This byte is a counter indicating the next segment to execute as an off-line data collection activity. Because the number of segments is 1, 01h
is always returned in this field.
MMCRE64GXMSP-0VA
MMDOE28GXMSP-0VA
0
2
3
4
5
6
Current Self-test execution status.
Automatic Off-line Data Collection is disabled.
Automatic Off-line Data Collection is enabled.
Percent Self-test remaining. An approximation of the percent of the self-test routine remaining until completion given in ten
percent increments. Valid values are 0 through 9.
0
1
2
3
4
5
6
7
15
Off-line data collection never started.
All segments completed without errors. In this case the current segment pointer is equal to the total segments required.
Off-line activity in progress.
Off-line data collection is suspended by the interrupting command.
Off-line data collecting is aborted by the interrupting command.
Off-line data collection is aborted with a fatal error.
Definition
Definition
The self-test routine completed without error or has never been run.
The self-test routine was aborted by the host.
The self-test routine was interrupted by the host with a hard or soft reset.
The device was unable to complete the self-test routine due to a fatal error or unknown test error.
The self-test routine was completed with an unknown element failure.
The self-test routine was completed with an electrical element failure.
The self-test routine was completed with a servo element failure.
The self-test routine was completed with a read element failure.
The self-test routine is in progress.
26
Revision 1.0
Final

Related parts for mmdoe28gxmsp-0va