efm-0322 Astrodyne Corporation, efm-0322 Datasheet - Page 2

no-image

efm-0322

Manufacturer Part Number
efm-0322
Description
30w Ultraminiature Open Frame Switching Power Supplies
Manufacturer
Astrodyne Corporation
Datasheet
All specifications are typical at nominal input, full load, and 25°C unless other-
wise noted
INPUT SPECIFICATIONS
Input Voltage Range
Frequency Range
Inrush Current, typ:
OUTPUT SPECIFICATIONS
Voltage and Current
Load Regulation *3
Line Regulation (LL-HL)
Cross Regulation
Preset Accuracy (FL,120VAC)
DC Voltage Adjust (typ)
Temperature Coefficient
Ripple/Noise *1, 4
Over Voltage Protection
Current Limit (auto recover)
Short Circuit Protection
Hold Up Time
*
may adversely affect long term reliability. Proper operation under conditions
other than the standard operating conditions is neither warranteed nor implied.
3 0 W U lt r aminiat ur e O p en Fr a me Swit ch i ng P ower Suppl ies
WWW.ASTRODYNE.COM
These are stress ratings. Exposure of the devices to any of these conditions
Duals:
Triples:
90-264 VAC
47-63 Hz
30A@115V, 60A@230V Input
See Selection Chart
See Selection Chart
±1%, max. (Singles & Duals)
0.6 / ±0.2%, max. (Triples)
±2%. max. (0308: ±2 / ±6%)
±3% max.
1% (0308: ±2 / ±5%)
1 / ±5%
±10% of FS (Primary)
±0.03%/°C (0-50°C, typ)
See Selection Chart
Latching Auto Recovery
>110% of FS, Power Limit
Latching Auto Recovery
20 mS, typ
*
*
*
Notes:
1. All measurements should be made directly at the terminals of the
power supply
2. Minimum Load is NOT required for proper operation. However, auxil-
iary outputs should be reduced as a function of primary output minimum
load or load reugulation will be higher.
3. Load Regulation measured from 20% to full load. All other outputs at
nominal load.
4. Output noise measured directky at pins at nomimnal load with 0.1uF
and 10uF capacitors, pk-pk @ 20MHz bandwidth.
GENERAL SPECIFICATIONS
Input-Out Isolation (1 min max.)
Efficiency
Switching Frequency
Safety
PHYSICAL SPECIFICATIONS
Size
Construction
Weight
ENVIRONMENTAL SPECIFICATIONS
Oper. Temperature (Free Air)
Storage Temperature
Relative Humidity
EMC
Astrodyne products are not authorized or warranteed for use
as critical components in life support systems, equipment used
in hazardous environments, nuclear controls systems, or other
mission-critical applications.
Singles:
Duals/Triples:
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
3KVAC
See Selection Chart
65Khz, (fixed, typical)
UL60950-1, EN60950-1
2.36” x 3.41” x 0.93”
2.36” x 3.94” x 0.93”
Open Frame
4.3oz (122g)
-10 to +70°C with Derate
-25 to +71°C
0 to + 95%, non-cond
EN55022, class II
E F M 3 0
*
*
s e r i e s