rr2ba-ul-ac6 IDEC Corporation, rr2ba-ul-ac6 Datasheet - Page 10

no-image

rr2ba-ul-ac6

Manufacturer Part Number
rr2ba-ul-ac6
Description
Ru/rr/rh/rm/ry & Latch Relays Relays Sockets
Manufacturer
IDEC Corporation
Datasheet
RU
Coil Ratings
Note 1: The rated current includes the current draw by the LED indicator.
Note 2: Rated voltage 100V DC is available for the bifurcated contact type only.
Contact Ratings
Note 1: On 4PDT relays, the maximum allowable total current of neighboring
Note 2: Inductive load for the rated load — cos ø = 0.3, L/R = 7 ms
• • • • UL and c-UL Ratings
• • • • CSA Ratings
• • • • TÜV Ratings
Surge Suppressor Ratings
10
bifurcated
250V AC 10A
250V AC
250V AC 10A
(50/60 Hz)
30V DC
30V DC
30V DC
Voltage
Voltage
Voltage
Contact
DPDT
AC Coil
DC Coil
4PDT
4PDT
Rated Voltage (V)
DC
AC
two poles is 6A. At the rated load, make sure that the total current of
neighboring two poles does not exceed 6A (3A + 3A = 6A).
Series
RU2 RU4 RU42 RU2 RU4 RU42 RU2
RU2 RU4 RU42 RU2 RU4 RU42
10A
10A
Continu-
Current
Type
100-110
110-120
200-220
220-240
10A
ous
6A
3A
100
110
Resistive
Resistive
Resistive
24
With Diode
12
24
48
RU42
With RC
6
6A
6A
6A
3A
3A
Allowable Contact Power
2500VA AC
1500VA AC
750VA AC
300W DC
180W DC
Universal Relays
Resistive
90W DC
3A
3A
Load
3A
3A
Voltage
Code
A24
A100
A110
A200
A220
D6
D12
D24
D48
D100
D110
Coil
RC series circuit
R: 20 kΩ, C: 0.033 µF
Diode reverse voltage: 1000V
Diode forward current: 1A
5A
5A
General Use
1250VA AC
600VA AC
200VA AC
150W DC
Inductive
Inductive
90W DC
45W DC
9.2-11.0
8.4-10.0
0.8A
1.5A
4.6-5.5
4.2-5.0
Rated Current (mA)
50 Hz
Load
6A
49.3
±15% (at 20°C)
0.8A
1.5A
44.7
155
9.7
8.9
80
18
Voltage
250 AC
250 AC
250 AC
Ratings
30 DC
30 DC
30 DC
7.8-9.0
7.1-8.2
4.0-4.6
3.6-4.2
60 Hz
(V)
42.5
Horse Power Rating
1/10HP
Load
Res.
10A
10A
RU4
Rated Load
3A
3A
3A
3A
Coil Resistance (Ω)
±10% (at 20°C)
Load
RU42
0.8A
1.5A
0.8A
1.5A
Ind.
14,080
18,230
10,000
12,100
5A
5A
3,460
4,550
2,560
164
160
605
40
Specifications
Note: Above values are initial values.
∗1: Measured using 5V DC, 1A voltage drop method
∗2: Measured at operating frequency of 120 operations/min (failure rate level
∗3: Measured at the rated voltage (at 20°C), excluding contact bouncing;
∗4: Contact Load and Electrical Life (at ambient temperature 20°C)
∗5: Measured at the rated voltage. Simple types include plug-in terminal sim-
Type (Contact)
Contact Material
Contact
Resistance
Minimum
Applicable Load ∗2
Operate Time
Release Time
Power
Consumption
Insulation
Resistance
Dielectric Strength
Operating
Frequency
Vibration
Resistance
Shock Resistance
Mechanical Life
Electrical Life
Operating
Temperature
Operating Humidity
Weight
RU2
RU4
RU42
Type
P, reference value)
Release time of AC relays with RC:
Release time of DC relays with diode:
ple types and all PCB terminal types.
Maximum Continuous
250V AC
110V DC
250V AC
110V DC
250V AC
110V DC
Voltage
30V DC
30V DC
30V DC
Applied Voltage
Operating Characteristics (against rated values at 20°C)
110%
110%
Resistive Load
∗1
∗3 20 ms maximum
∗3 20 ms maximum
∗4 See table below
∗5
0.65A
0.33A
0.44A
0.6A
Silver alloy
50 mΩ maximum
24V DC, 5 mA
(reference value)
AC: 1.1 to 1.4VA (50 Hz), 0.9 to 1.2VA (60 Hz)
DC: 0.9 to 1.0W
100 MΩ minimum (500V DC megger)
Between contact and coil: 2500V AC, 1 minute
Between contacts of different poles:
2500V AC,
1 minute
Between contacts of the same pole:
1000V AC, 1 minute
Electrical:
Mechanical: 18,000 operations/h maximum
Damage limits:
Operating extremes: 10 to 55 Hz, amplitude 0.5 mm
Damage limits:
Operating extremes: 150 m/s
AC: 50,000,000 operations
DC: 100,000,000 operations
Simple types:
Others:
5 to 85% RH (no condensation)
Approx. 35g
10A
10A
5A
5A
3A
6A
3A
3A
3A
6
RU2 (DPDT)
(cos ø = 0.3, L/R = 7 ms)
Minimum Pickup
80% maximum
80% maximum
1800 operations/h maximum
Inductive Load
Voltage
Silver
(gold clad)
1V DC, 1 mA
2000V AC, 1 minute
–55 to +70°C (no freezing)
–55 to +60°C (no freezing)
0.33A
0.18A
0.22A
2.5A
2.5A
0.4A
2.6A
0.8A
2.7A
1.5A
0.8A
1.5A
5A
5A
RU4 (4PDT)
10 to 55 Hz, amplitude 0.5 mm
1000 m/s
25 ms maximum
40 ms maximum
2
2
(operations minimum)
Dropout Voltage
10% maximum
30% minimum
Silver-nickel
(gold clad)
1V DC, 0.1 mA
50,000,000
operations
Electrical Life
RU42 (4PDT)
100,000
500,000
100,000
500,000
100,000
200,000
200,000
200,000
100,000
100,000
100,000
50,000
50,000
50,000
(04/10/25)

Related parts for rr2ba-ul-ac6