Datasheet
Table 8 –EEPROM Memory Content (A2h)
0
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
56
60
64
68
72
76
78
80
82
84
86
88
90
92
95
96
Addr.
00
02
04
06
08
0A
0C
0E
10
12
14
16
18
1A
1C
1E
20
22
24
26
28
38
3C
40
44
48
4C
4E
50
52
54
56
58
5A
5C
5F
60
Field Size
(Bytes)
16
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
4
4
4
4
4
2
2
2
2
2
2
2
2
3
1
2
TX_PWR(Slope) Calibration
TX_PWR(Offset) Calibration
Transceiver Temperature
TX Power High Warning
RX Power High Warning
RX Power Low Warning
RX_PWR(4) Calibration
RX_PWR(3) Calibration
RX_PWR(2) Calibration
RX_PWR(1) Calibration
RX_PWR(0) Calibration
TX Power Low Warning
TX_I(Slope) Calibration
TX_I(Offset) Calibration
Voltage High Warning
TX Power High Alarm
RX Power High Alarm
Voltage Low Warning
RX Power Low Alarm
TX Power Low Alarm
T(Offset) Calibration
V(Offset) Calibration
Temp High Warning
T(Slope) Calibration
V(Slope) Calibration
Temp Low Warning
Voltage High Alarm
Voltage Low Alarm
Name of Field
Bias High Warning
Bias Low Warning
Temp High Alarm
Temp Low Alarm
Bias High Alarm
Bias Low Alarm
Checksum
Reserved
Reserved
00 00 00 00
00 00 00 00
00 00 00 00
3F 80 00 00
00 00 00 00
00….000
00 00 00
8C A0
AF C8
07 CB
4B 00
88 B8
88 B8
7B 86
22 D0
6E 17
50 00
F3 00
F8 00
75 30
79 18
00 00
00 00
27 10
00 0F
06 30
00 14
01 00
00 00
01 00
00 00
01 00
00 00
01 00
00 00
Hex
xx xx
xx
SPS-34-24T-HP-CDFA
2nd order RSSI calibration coefficient
3rd order RSSI calibration coefficient
0th order RSSI calibration coefficient
Offset for Temperature calibration, in
4th order RSSI calibration coefficient
1st order RSSI calibration coefficient
Slope for Temperature calibration
Offset for TX Power calibration
Slope for TX Power calibration
DS-6181 Rev 03 2011-08-11
Offset for VCC calibration
Offset for Bias calibration
Slope for VCC calibration
Slope for Bias calibration
Temperature in C/256
units of 256ths C
Description
Checksum
Reserved
Reserved
-0.5dBm
4.5dBm
-28dBm
-27dBm
-7dBm
-8dBm
-13
90mA
70mA
5dBm
0dBm
80
75
-8
3.6V
3.0V
3.5V
3.1V
0mA
0mA