il3285etr13 NVE Corp., il3285etr13 Datasheet
il3285etr13
Related parts for il3285etr13
il3285etr13 Summary of contents
Page 1
Fractional Load RS-485 and RS-422 Isolated Transceivers Functional Diagrams DE V COIL1 IL3285 DE V COIL1 IL3222 IL3285 Truth Table (A-B) ≥ 200 ≤−200 mV H ...
Page 2
Absolute Maximum Ratings Operating at absolute maximum ratings will not damage the device. However, extended periods of operation at the absolute maximum ratings may affect performance and reliability. Parameters Storage Temperature Ambient Operating Temperature Voltage Range ...
Page 3
IL3285-3 Pin Connections (0.15" SOIC Package Input power supply DD1 2 GND Ground return for Output data from bus 3 Read enable high high impedance) DE Drive enable ...
Page 4
IL3285 Pin Connections (0.3" SOIC Package Input power supply DD1 2 GND Ground return for Output data from bus 3 Read enable high high impedance) DE Drive enable ...
Page 5
Driver Section Electrical specifications are unless otherwise stated. min max Parameters Coil Input Impedance Temperature Coefficient of Coil Resistance Output voltage Differential Output Voltage Differential Output Voltage (6) Differential Output Voltage (7) Change in Magnitude of Differential ...
Page 6
Receiver Section Electrical specifications are unless otherwise stated. min max Parameters Coil Input Impedance Temperature Coefficient of Coil Resistance Positive-going Input Threshold Negative-going Input Threshold − V Hysteresis Voltage (V ) it+ it− High Level Digital Output ...
Page 7
Power Supply Decoupling Both V and V must be bypassed with 47 nF ceramic capacitors. These should be placed as close as possible to V DD1 DD2 proper operation. Additionally, V should be bypassed with a 10 µF tantalum capacitor. ...
Page 8
Method Field applied in direction H1 Field applied in direction H2 Field applied in any direction but with field booster capacitor (1 nF) in circuit Table 1. Magnetic Immunity Data Rate and Magnetic Field Immunity It is easier to disrupt ...
Page 9
Cable Length (feet) 100 40 Figure 3. Cable Length vs. Data Rate (30% jitter). Terminations: Transmission lines should be terminated to avoid reflections that cause data errors. In RS-485 systems both ends of the bus, not every node, ...
Page 10
Fail-Safe Operation: “Fail-safe operation” is defined here as the forcing of a logic high state on the “R” output in response to an open-circuit condition between the “A” and “B” lines of the bus, or when no drivers are active ...
Page 11
Package Drawings, Dimensions and Specifications 0.15" 16-pin SOIC 0.386 (9.8) 0.394 (10.0) Pin 1 identified by either an indent or a marked dot 0.228 (5.8) 0.244 (6.2) 0.3" 16-pin SOIC 0.397 (10.1) 0.413 (10.5) Pin 1 identified by either an ...
Page 12
Ordering Information and Valid Part Numbers IL 3285 -3 E TR13 NVE Corporation 11409 Valley View Road, Eden Prairie, MN 55344-3617 Bulk Packaging Blank = Tube TR13 = 13'' Tape and Reel Package E = RoHS Compliant Package Type Blank ...
Page 13
Revision History ISB-DS-001-IL3285/22-H Changes • February 2008 • ISB-DS-001-IL3285/22-G Changes • ISB-DS-001-IL3285/22-F Changes • ISB-DS-001-IL3285/22-E Changes • ISB-DS-001-IL3285/22-D Changes • • • ISB-DS-001-IL3285/22-C Changes ISB-DS-001-IL3285/22-B Revision A not released ISB-DS-001-IL3285/22-A Internal Release ONLY NVE Corporation 11409 ...
Page 14
About NVE An ISO 9001 Certified Company NVE Corporation manufactures innovative products based on unique spintronic Giant Magnetoresistive (GMR) technology. Products include Magnetic Field Sensors, Magnetic Field Gradient Sensors (Gradiometers), Digital Magnetic Field Sensors, Digital Signal Isolators, and Isolated Bus ...