Open Daisy Chain Protection
IR3500 checks the daisy chain every time it powers up. It starts a daisy chain pulse on the PHSOUT pin and
detects the feedback at PHSIN pin. If no pulse comes back after 32 CLKOUT pulses, the pulse is restarted again. If
the pulse fails to come back the second time, the open daisy chain fault is registered, and SS/DEL is not allowed to
charge. The fault latch can only be reset by cycling the power to VCCL.
After powering up, the IR3500 monitors PHSIN pin for a phase input pulse equal or less than the number of phases
detected. If PHSIN pulse does not return within the number of phases in the converter, another pulse is started on
PHSOUT pin. If the second started PHSOUT pulse does not return on PHSIN, an open daisy chain fault is
registered.
Phase Number Determination
After a daisy chain pulse is started, the IR3500 checks the timing of the input pulse at PHSIN pin to determine the
phase number. This information is used to have symmetrical phase delay between phase switching without the
need of any external component.
Single Phase Operation
In an architecture where only a single phase is needed the switching frequency is determined by the clock
frequency.
Page 27 of 47
OV
THRESHOLD
OUTPUT
VOLTAGE
(VO)
VID
(FAST
VDAC)
VDAC
NORMAL
OPERATION
Figure 19 - Over-voltage protection during dynamic VID
VDAC
VID DOWN
50mV
LOW VID
50mV
VID UP
NORMAL
OPERATION
1.73V
June 12, 2007
VDAC + 130mV
IR3500