ade7166 Analog Devices, Inc., ade7166 Datasheet - Page 66

no-image

ade7166

Manufacturer Part Number
ade7166
Description
Single-phase Energy Measurement Ic With 8052 Mcu, Rtc, And Lcd Driver
Manufacturer
Analog Devices, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ade7166ASTZF16
Manufacturer:
VHK
Quantity:
2
Part Number:
ade7166ASTZF16
Manufacturer:
Analog Devices Inc
Quantity:
10 000
Part Number:
ade7166ASTZF16-RL
Manufacturer:
KOA
Quantity:
50 000
Part Number:
ade7166ASTZF16-RL
Manufacturer:
Analog Devices Inc
Quantity:
10 000
Part Number:
ade7166ASTZF8
Manufacturer:
Analog Devices Inc
Quantity:
10 000
Part Number:
ade7166ASTZF8-RL
Manufacturer:
Analog Devices Inc
Quantity:
10 000
ADE7566/ADE7569/ADE7166/ADE7169
Integration Time Under Steady Load: Reactive Energy
As mentioned in the Active Energy Calculation section, the
discrete time sample period (T) for the accumulation register is
1.22 μs (5/MCLK). With full-scale sinusoidal signals on the
analog inputs and the VARGAIN and VARDIV registers set to
0x000, the integration time before the reactive energy register
overflows is calculated in Equation 26.
When VARDIV is set to a value different from 0, the integration
time varies, as shown in Equation 27.
Reactive Energy Accumulation Modes
VAR Signed Accumulation Mode
The ADE7569/ADE7169 reactive energy default accumulation
mode is a signed accumulation based on the reactive power
information.
VAR Antitamper Accumulation Mode
The ADE7569/ADE7169 are placed in VAR antitamper
accumulation mode by setting the SAVARM bit in the ACCMODE
register (0x0F). In this mode, the reactive power is accumulated
depending on the sign of the active power. When active power
is positive, the reactive power is added as it is to the reactive
energy register. When active power is negative, the reactive
power is subtracted from the reactive energy accumulator (see
Figure 72). The CF pulse also reflects this accumulation method
when in this mode. The default setting for this mode is off.
Transitions in the direction of power flow and no-load threshold
are active in this mode.
Time =
Time
0xFFFF,
0xCCCCD
=
Time
FFFF,
WDIV
FFFF
=0
×
×
VARDIV
. 1
22
μ
s
=
409
6 .
sec
=
. 6
82
min
Rev. A | Page 66 of 144
(26)
(27)
REACTIVE ENERGY
REACTIVE POWER
ACTIVE POWER
APSIGN FLAG
THRESHOLD
THRESHOLD
THRESHOLD
THRESHOLD
NO-LOAD
NO-LOAD
NO-LOAD
NO-LOAD
Figure 72. Reactive Energy Accumulation in
Antitamper Accumulation Mode
INTERRUPT STATUS REGISTERS
POS
NEG
POS

Related parts for ade7166