adm202e Analog Devices, Inc., adm202e Datasheet - Page 13

no-image

adm202e

Manufacturer Part Number
adm202e
Description
Emi/emc-compliant, ?15 Kv, Esd-protected Rs-232 Line Drivers/receivers
Manufacturer
Analog Devices, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
adm202eA
Manufacturer:
AD
Quantity:
3
Part Number:
adm202eA
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
adm202eAN
Manufacturer:
AD
Quantity:
6 500
Part Number:
adm202eAN
Manufacturer:
Analog Devices Inc.
Quantity:
2 000
Part Number:
adm202eAN
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
adm202eANZ
Manufacturer:
VISHAY
Quantity:
21 535
Part Number:
adm202eANZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
adm202eARN
Manufacturer:
AD
Quantity:
130
Part Number:
adm202eARN
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
adm202eARN-REEL
Manufacturer:
AD
Quantity:
1 000
Part Number:
adm202eARN-REEL
Manufacturer:
AD
Quantity:
18
Part Number:
adm202eARN-REEL
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Company:
Part Number:
adm202eARNZ
Quantity:
48
Company:
Part Number:
adm202eARNZ-REEL
Quantity:
2 815
RADIATED EMISSIONS
Radiated emissions are measured at frequencies in excess of
30 MHz. RS-232 outputs are designed for operation at high
baud rates, while driving cables can radiate high frequency EM
energy. The previously described causes of conducted emissions
can also cause radiated emissions. Fast RS-232 output transitions
can radiate interference, especially when lightly loaded and
driving unshielded cables. Charge-pump devices are also prone
to radiating noise due to the high frequency oscillator and the
high voltages being switched by the charge pump. The move
toward smaller capacitors to conserve board space has resulted
in higher frequency oscillators in the charge-pump design,
causing higher levels of conducted and radiated emissions.
The RS-232 outputs on the ADM202E feature a controlled slew
rate to minimize the level of radiated emissions, yet they are fast
enough to support data rates of up to 230 kBaud.
Figure 27 shows radiated emissions vs. frequency. The levels of
emissions are well within specifications without the need for
additional shielding or filtering components. The ADM202E
80
70
60
50
40
30
20
10
0
0.3
Figure 25. ADM202E Conducted Emissions
0.6
LOG FREQUENCY (MHz)
1
3
6
10
30
LIMIT
Rev. C | Page 13 of 16
was operated at maximum baud rates and configured like a
typical RS-232 interface. Testing for radiated emissions was
carried out in a shielded anechoic chamber.
80
70
60
50
40
30
20
10
0
START 30.0MHz
Figure 27. ADM202E Radiated Emissions vs. Frequency
DUT
RADIATED NOISE
TURNTABLE
Figure 26. Radiated Emissions Test Setup
ADJUSTABLE
ANTENNA
ADM202E/ADM1181A
STOP 200.0MHz