Figure 1. Block Diagram
July 2003
FAULT TOLERANT DIFFERENTIAL
CAN TRANSCEIVER
OPERATING SUPPLY VOLTAGE 6V TO 28V,
TRANSIENTS UP TO 40V
LOW QUIESCENT CURRENT IN STANDBY
MODE (100 A) AND SLEEP MODE (37 A)
ON CHIP DIAGNOSIS FOR ERRORS ON THE
PHYSICAL BUSLINES WITH MICRO
CONTROLLER INTERFACE
OPTIMIZED EMI BEHAVIOUR DUE TO LIMITED
AND SYMMETRIC SLOPES OF CAN SIGNALS
AUTOMATIC SWITCHING TO SINGLE WIRE
MODE UPON BUS FAILURES
TWO-EDGE SENSITIVE WAKE-UP PIN
SUPPORTS TRANSMISSION WITH GROUND
SHIFT VOLTAGES:
SINGLE WIRE: 1.5V
DIFFERENTIAL WIRE: 3v
AN UNPOWERED NODE OR UNSUFFICIENT
WAKE
99AT0001
NSTB
TXD
EN
KL30
(+12V)
2
5
6
7
100k
5Vint
VCC
12.5k
75k
100k
Wake-up
Control
Control
Power
Low
FAULT TOLERANT CAN TRANSCEIVER
Management
& Diagnosis
14
VS
Control
TXD
Error
Receiver
1
INH
13
Regulator
Voltage
GND
CANH
CANH
Driver
Driver
+5V
DESCRIPTION
The L9669 is an integrated circuit which contains a
CAN physical line interface. It integrates all main lo-
cal functions for automotive body electronic applica-
tions connected to a CAN bus.
CANH Termination
CANL Termination
SUPPLIES DO NOT DISTURB THE BUS
LINES
10
VCC
Filter
ORDERING NUMBER: L9669
11 CANH
12 CANL
3
8
9
4
RXD
RTH
RTL
NERR
R
RTH
SO14
R
RTL
CAN
BUSLINE
L9669
1/13

Related parts for l9669

l9669 Summary of contents

Page 1

... FAULT TOLERANT CAN TRANSCEIVER ORDERING NUMBER: L9669 SUPPLIES DO NOT DISTURB THE BUS LINES DESCRIPTION The L9669 is an integrated circuit which contains a CAN physical line interface. It integrates all main lo- cal functions for automotive body electronic applica- tions connected to a CAN bus. +5V Voltage ...

Page 2

... L9669 Figure 2. Pin Connection top view. 99AT0002 Table 1. Pin Functions N° Pin 1 INH Inhibit Output - for switching external 5V Regulator 2 TXD Transmit Data Input - active LOW dominant Bit transmission 3 RXD Receive Data Output - active LOW dominant Bit reception 4 NERR Error/Diagnostic Output - active LOW error/Wake-up and Diagnostic output ...

Page 3

... bus errors TXD CC R < 4k RTH TXD I = -40mA CANH TXD CC R < 4k RTH L9669 Value Unit -0.3 to +28 V -0.3 to + -28 to + -55 to +150 o C -40 to +150 o C Min. Typ. Max. ...

Page 4

... L9669 Table 4. Electrical Characteristcs (continued 4.75V to 5.25V 28V Item Symbol Parameter 2.6 V CANL dominant output voltage CANLd 2.7 I CANH output current CANH 2.8 I CANL output current CANL 2.9 I CANH leakage current CANHl 2.10 I CANL leakage current CANLl 2.11 V CANH wake-up voltage CANHWK 2.12 V CANL wake-up voltage CANLWK 2 ...

Page 5

... Error 1.5V RTL CC Sleep/standby mode RTL , Sleep/standby mode I = 1mA RTH TXD TXD I = -0.18mA INH ) Not sleep mode INH Sleep mode. L9669 Min. Typ. Max. Unit - 0 0.9 0 0.9 V -200 ...

Page 6

... L9669 Table 4. Electrical Characteristcs (continued 4.75V to 5.25V 28V Item Symbol Parameter 7 Inputs NSTB, EN 7.1 V High level input voltage Xh 7.2 V Low level input voltage Xl 7.3 I High level input current Xh 7.4 I Low level input current Xl 8 Input WAKE 8.1 V WAKE high level input voltage WAKEh 8 ...

Page 7

... FUNCTIONAL DESCRIPTION The L9669 is a monolithic integrated circuit which provides all main functions for an automotive body CAN sys- tem. The device guarantees a clearly defined behavior in case of failure to avoid permanent CAN bus errors primarily intended for low speed applications in passenger cars. ...

Page 8

... L9669 Figure 3. NSTB = NSTB = Power on RX only NSTB = 0 Mode Mode NSTB EN INH 99AT0003 8/13 Standby Mode NSTB EN INH NSTB = NSTB = NSTB = 0 "Go to Sleep" Mode NSTB EN INH 0 1 Float. NSTB = Sleep Mode NSTB EN INH ...

Page 9

... Data are received on CANH or CANL after short circuit was detected. Error 10: Data are received normally, error is detected by protocol unit. Upon any error in normal or RXonly mode the NERR output will be forced LOW and released after error recovery. Type of Errors L9669 Severity ...

Page 10

... L9669 1.4 Diagnosis A serial interface is available to retrieve diagnostic informations. Diagnostic data can be requested by using EN as serial clock and evaluating NERR. Figure 4. NSTB EN Bus Error detected NERR Mode Normal (Example) Delay between falling slope at EN and reaction at NERR: 0.7 (NERR is synchronized with internal clock). ...

Page 11

... Transceiver 10 CANL 12 TXD 2 RTL RXD 9 3 NERR 4 NSTB GND INH VS VCC NSTB WAKE 7 TXD 2 11 NERR RXD GND 20pF L9669 KL30 (+12V) Voltage Regulator +5V CAN Controller RTL CANL C 2 CANH RTH 11/13 ...

Page 12

... L9669 mm DIM. MIN.. TYP. MAX.. MIN.. A 1.75 a1 0.1 0.25 0.004 a2 1.6 b 0.35 0.46 0.014 b1 0.19 0.25 0.007 C 0.5 c1 45˚ (typ.) D (1) 8.55 8.75 0.336 E 5.8 6.2 0.228 e 1.27 e3 7.62 F (1) 3.8 4 0.150 G 4.6 5.3 0.181 L 0.4 1.27 0.016 M 0.68 S 8˚ (max.) (1) D and F do not include mold flash or protrusions. Mold flash or potrusions shall not exceed 0.15mm (.006inch). ...

Page 13

... The ST logo is a registered trademark of STMicroelectronics Australia - Brazil - Canada - China - Finland - France - Germany - Hong Kong - India - Israel - Italy - Japan -Malaysia - Malta - Morocco - Singapore - Spain - Sweden - Switzerland - United Kingdom - United States. 2003 STMicroelectronics - All Rights Reserved  STMicroelectronics GROUP OF COMPANIES http://www.st.com L9669 13/13 ...

Related keywords