mlx90333 Melexis Company, mlx90333 Datasheet - Page 28

no-image

mlx90333

Manufacturer Part Number
mlx90333
Description
Triaxis? 3d-joystick Position Sensor
Manufacturer
Melexis Company
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
mlx90333EDC-BCT-000-RE
Manufacturer:
MICRON
Quantity:
1 001
Part Number:
mlx90333EGO-BCH
Manufacturer:
MELEXIS/迈来芯
Quantity:
20 000
Part Number:
mlx90333KDC-BCH-000-SP
Manufacturer:
Melexis
Quantity:
1 200
Part Number:
mlx90333KDC-BCH-000-TU
Manufacturer:
FREESCALE
Quantity:
101
Part Number:
mlx90333KDC-BCH-100-RE
Manufacturer:
Melexis
Quantity:
1 200
Part Number:
mlx90333KDC-BCH-100-SP
Manufacturer:
Melexis
Quantity:
1 400
Part Number:
mlx90333KDC-BCT
Manufacturer:
MELEXIS/迈来芯
Quantity:
20 000
Part Number:
mlx90333KDC-BCT-000-RE
Manufacturer:
MELEXIS/迈来芯
Quantity:
20 000
Part Number:
mlx90333LDC-BCH-000
Manufacturer:
MELEXIS/迈来芯
Quantity:
20 000
Part Number:
mlx90333LGO-BGT-000-TU
Manufacturer:
MELEXIS/迈来芯
Quantity:
20 000
14.7. Programmable Diagnostic Settings
14.7.1. RESONFAULT Parameter
This RESONFAULT parameter enables the soft reset when a fault is detected by the CPU when the
parameter is set to 1. By default, the parameter is set to “0” but it is recommended to set it to “1” to
activate the self diagnostic modes (See section 15).
Note that in the User Interface (MLX90333UI), the RESONFAULT is a cluster of the following two bits, i.e.
the 2 bits are both disabled or both enabled:
14.7.2. EEHAMHOLE Parameter
The EEHAMHOLE parameter disables the memory recovery (Hamming code) check when a fault is
detected by the CRC when it is equal to 3131h. By default the parameter is set to 0 (enable memory
recovery).
14.8. Lock
14.8.1. MLXLOCK Parameter
MLXLOCK locks all the parameters set by Melexis.
14.8.2. LOCK Parameter
LOCK locks all the parameters set by the user. Once the lock is enabled, it is not possible to change the
EEPROM values anymore.
Note that the lock bit should be set by the solver function “MemLock”.
3901090333
Rev. 001
DRESONFAULT: disable the reset in case of a fault.
DOUTINFAULT: disable output in diagnostic low in case of fault.
RESONFAULT
EEHAMHOLE
Parameter
Parameter
MLXLOCK
LOCK
Page 28 of 43
Tria ⊗ is ™ 3D-Joystick Position Sensor
3131h
Value
Value
0
1
0
0
1
0
1
Unit
Unit
MLX90333
Data Sheet
Jan 08

Related parts for mlx90333