adl5505 Analog Devices, Inc., adl5505 Datasheet - Page 5

no-image

adl5505

Manufacturer Part Number
adl5505
Description
450 Mhz To 6000 Mhz Trupwr Detector Adl5505
Manufacturer
Analog Devices, Inc.
Datasheet
Parameter
RF INPUT (f = 6000 MHz)
VRMS OUTPUT
POWER SUPPLIES
1
2
3
4
5
6
The available output swing and, therefore, the dynamic range are altered by the supply voltage; see Figure 8.
Error referred to delta from 25°C response; see Figure 13, Figure 14, Figure 15, Figure 19, Figure 20, and Figure 21.
Error referred to best-fit line at 25°C; see Figure 10, Figure 11, Figure 12, Figure 16, Figure 17, and Figure 18.
Calculated using linear regression.
The response time is measured from 10% to 90% of settling level; see Figure 30 and Figure 31.
Supply current is input level-dependent; see Figure 27.
Input Impedance
RMS Conversion
Output Offset
Maximum Output Voltage
Available Output Current
Pulse Response Time
Power-Up Response Time
Operating Range
Quiescent Current
Dynamic Range
Maximum Input Level
Minimum Input Level
Conversion Gain
Output Intercept
Output Voltage, High Input Power
Output Voltage, Low Input Power
Temperature Sensitivity
±1 dB Error
±2 dB Error
3
3
1
6
4
5
Test Conditions
Input RFIN to output VRMS
No termination
Continuous wave (CW) input, −40°C < T
±0.25 dB error
±1 dB error
VRMS = (gain × V
P
P
P
+25°C < T
−40°C < T
Pin VRMS
No signal at RFIN
V
C
C
−40°C < T
No signal at RFIN
IN
IN
IN
S
OUT
OUT
= 3.0 V, R
= 5 dBm, 400 mV rms
= −15 dBm, 40 mV rms
= 0 dBm
= open, 10 dB step, 10% to 90% of settling level
= open, 0 dBm at RFIN
A
A
A
< +85°C
< +25°C
< +85°C
3
LOAD
3
≥ 10 kΩ
Rev. 0 | Page 5 of 20
IN
) + intercept
A
< +85°C
Min
2.5
Typ
80||0.42
23
33
11
−17
0.77
0.002
0.298
0.032
0.0103
0.0138
10
2.5
3
3
3
1.8
Max
100
3.3
ADL5505
Unit
Ω||pF
dB
dB
dBm
dBm
V/V rms
V
V
V
dB/°C
dB/°C
mV
V
mA
μs
μs
V
mA