is42sm16200c Integrated Silicon Solution, Inc., is42sm16200c Datasheet - Page 9

no-image

is42sm16200c

Manufacturer Part Number
is42sm16200c
Description
1m X 16bits X 2banks Low Power Synchronous Dram
Manufacturer
Integrated Silicon Solution, Inc.
Datasheet
Rev. 00A | July 2010
Bank(Row) Active
The Bank Active command is used to activate a row in a specified bank of the device. This command is initiated by activating CS, RAS and
Read
The READ command is used to initiate the burst read of data. This command is initiated by activating CS, CAS, and deasserting WE, RAS at
Write
The WRITE command is used to initiate the burst write of data. This command is initiated by activating CS, CAS, WE and deasserting RAS
Burst Length
Read and write accesses to the SDRAM are burst oriented, with the burst length being programmable, as shown in Figure 4. The burst
length determines the maximum number of column locations that can be accessed for a given READ or WRITE command Burst
length determines the maximum number of column locations that can be accessed for a given READ or WRITE command. Burst
lengths of 1, 2, 4 or 8 locations are available for both the sequential and the interleaved burst types, and a full-page burst is available
for the sequential type. The full-page burst is used in conjunction with the BURST TERMINATE command to generate arbitrary burst
lengths.
Reserved states should not be used, as unknown operation or incompatibility with future versions may result. When a READ or WRITE
command is issued, a block of columns equal to the burst length is effectively selected. All accesses for that burst take place within
this block, meaning that the burst will wrap within the block if a boundary is reached. The block is uniquely selected by A1-A8 when
the burst length is set to two; by A2-A8 when the burst length is set to four; and by A3-A8 when the burst length is set to eight. The
remaining (least significant) address bit(s) is (are) used to select the starting location within the block. Full-page bursts wrap within
the page if the boundary is reached.
deasserting CAS, WE at the positive edge of the clock. The value on the BA selects the bank, and the value on the A0-A10 selects the row.
This row remains active for column access until a precharge command is issued to that bank. Read and write operations can only be
initiated on this activated bank after the minimum tRCD time is passed from the activate command.
the positive edge of the clock. BA input select the bank, A0-A8 address inputs select the starting column location. The value on input A10
determines whether or not Auto Precharge is used. If Auto Precharge is selected the row being accessed will be precharged at the end of
the READ burst; if Auto Precharge is not selected, the row will remain active for subsequent accesses. The length of burst and the CAS
latency will be determined by the values programmed during the MRS command.
at the positive edge of the clock. BA input select the bank, A0-A8 address inputs select the starting column location. The value on input
A10 determines whether or not Auto Precharge is used If Auto Precharge is selected the row being accessed will be precharged at the
A10 determines whether or not Auto Precharge is used. If Auto Precharge is selected the row being accessed will be precharged at the
end of the WRITE burst; if Auto Precharge is not selected, the row will remain active for subsequent accesses.
g
; y
www.issi.com
g
- dram@issi.com
;
y
IS42SM/RM/VM16200C
g
Advanced Information
g
9