m29f800dt STMicroelectronics, m29f800dt Datasheet - Page 11

no-image

m29f800dt

Manufacturer Part Number
m29f800dt
Description
8 Mbit 1mb X8 Or 512kb X16, Boot Block 5v Supply Flash Memory
Manufacturer
STMicroelectronics
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
m29f800dt-55M1
Manufacturer:
ST
0
Part Number:
m29f800dt-55M1F
Manufacturer:
ST
0
Part Number:
m29f800dt-55N1
Manufacturer:
ST
0
Part Number:
m29f800dt-55N1F
Manufacturer:
ST
0
Part Number:
m29f800dt-55N6
Manufacturer:
ST
0
Part Number:
m29f800dt-70M6
Manufacturer:
ST
Quantity:
2 000
Part Number:
m29f800dt-70N1
Manufacturer:
ST
Quantity:
147
Company:
Part Number:
m29f800dt-70N1
Quantity:
210
Part Number:
m29f800dt-70N3
Manufacturer:
ST
Quantity:
20 000
Part Number:
m29f800dt-70N6
Manufacturer:
ST
Quantity:
2 300
Part Number:
m29f800dt-70N6
Manufacturer:
ST
Quantity:
2 300
Part Number:
m29f800dt-70N6
Manufacturer:
ST
Quantity:
3 272
Part Number:
m29f800dt-70N6
Manufacturer:
ST
Quantity:
20 000
Table 3. Bus Operations, BYTE = V
Note: X = V
COMMAND INTERFACE
All Bus Write operations to the memory are inter-
preted by the Command Interface. Commands
consist of one or more sequential Bus Write oper-
ations. Failure to observe a valid sequence of Bus
Write operations will result in the memory return-
ing to Read mode. The long command sequences
are imposed to maximize data security.
The address used for the commands changes de-
pending on whether the memory is in 16-bit or 8-
bit mode. See either Table 4, or 5, depending on
the configuration that is being used, for a summary
of the commands.
Read/Reset Command. The Read/Reset com-
mand returns the memory to its Read mode where
it behaves like a ROM or EPROM, unless other-
wise stated. It also resets the errors in the Status
Register. Either one or three Bus Write operations
can be used to issue the Read/Reset command.
The Read/Reset Command can be issued, be-
tween Bus Write cycles before the start of a pro-
gram or erase operation, to return the device to
read mode. Once the program or erase operation
has started the Read/Reset command is no longer
accepted. The Read/Reset command will not
abort an Erase operation when issued while in
Erase Suspend.
Auto Select Command. The Auto Select com-
mand is used to read the Manufacturer Code, the
Device Code and the Block Protection Status.
Three consecutive Bus Write operations are re-
quired to issue the Auto Select command. Once
the Auto Select command is issued the memory
remains in Auto Select mode until a Read/Reset
command is issued. Read CFI Query and Read/
Reset commands are accepted in Auto Select
mode, all other commands are ignored.
Bus Read
Bus Write
Output Disable
Standby
Read Manufacturer
Code
Read Device Code
Operation
IL
or V
IH
.
V
V
V
V
V
E
X
IH
IL
IL
IL
IL
V
V
V
V
V
G
X
IH
IH
IL
IL
IL
IH
V
V
V
V
V
W
X
IH
IH
IH
IH
IL
Cell Address
Command Address
X
X
A0 = V
Others V
A0 = V
Others V
Address Inputs
IL
IH
, A1 = V
, A1 = V
IL
IL
From the Auto Select mode the Manufacturer
Code can be read using a Bus Read operation
with A0 = V
may be set to either V
Code for STMicroelectronics is 0020h.
The Device Code can be read using a Bus Read
operation with A0 = V
address bits may be set to either V
The Block Protection Status of each block can be
read using a Bus Read operation with A0 = V
A1 = V
the block. The other address bits may be set to ei-
ther V
then 01h is output on Data Inputs/Outputs DQ0-
DQ7, otherwise 00h is output.
Program Command. The Program command
can be used to program a value to one address in
the memory array at a time. The command re-
quires four Bus Write operations, the final write op-
eration latches the address and data in the internal
state machine and starts the Program/Erase Con-
troller.
If the address falls in a protected block then the
Program command is ignored, the data remains
unchanged. The Status Register is never read and
no error condition is given.
During the program operation the memory will ig-
nore all commands. It is not possible to issue any
command to abort or pause the operation. Typical
program times are given in Table 6. Bus Read op-
erations during the program operation will output
the Status Register on the Data Inputs/Outputs.
See the section on the Status Register for more
details.
After the program operation has completed the
memory will return to the Read mode, unless an
error has occurred. When an error occurs the
A0-A18
or V
or V
IH
IH
IL
IL
IL
IH
, A9 = V
, A9 = V
or V
, and A12-A18 specifying the address of
IL
IH
and A1 = V
. If the addressed block is protected
ID
ID
,
,
M29F800DT, M29F800DB
IL
IH
DQ15A–1, DQ14-DQ0
Data Inputs/Outputs
22ECh (M29F800DT)
2258h (M29F800DB)
or V
IL
and A1 = V
. The other address bits
Data Output
IH
Data Input
. The Manufacturer
0020h
Hi-Z
Hi-Z
IL
IL
or V
. The other
IH
.
11/39
IL
,

Related parts for m29f800dt