s-24c04c Seiko Instruments Inc., s-24c04c Datasheet - Page 23

no-image

s-24c04c

Manufacturer Part Number
s-24c04c
Description
2-wire Serial E2prom
Manufacturer
Seiko Instruments Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
s-24c04cI-K8T3U
Manufacturer:
IR
Quantity:
1 073
Part Number:
s-24c04cI-K8T3U
Manufacturer:
SII
Quantity:
3 202
Part Number:
s-24c04cI-K8T3U
Manufacturer:
SII/精工
Quantity:
20 000
Rev.2.0
3. Phase adjustment during S-24C04C access
[How to reset S-24C04C]
The S-24C04C does not have a pin to reset (the internal circuit). The users cannot forcibly reset it externally. If the
communication to the S-24C04C interrupted, the users need to handle it as you do for software.
In the S-24C04C, users are able to reset the internal circuit by inputting a start condition and a stop condition.
Although the reset signal is input to the master device, the S-24C04C’s internal circuit does not go in reset, but it does
by inputting a stop condition to the S-24C04C. The S-24C04C keeps the same status thus cannot do the next
operation. Especially, this case corresponds to that only the master device is reset when the power supply voltage
drops.
If the power supply voltage restored in this status, input the instruction after resetting (adjusting the phase with the
master device) the S-24C04C. How to reset is shown below.
SDA
SCL
The S-24C04C is able to be reset by a start and stop instructions. When the S-24C04C is reading data “0” or is
outputting the acknowledgment signal, outputs “0” to the SDA line. In this status, the master device cannot output
an instruction to the SDA line. In this case, terminate the acknowledgment output operation or the Read operation,
and then input a start instruction. Figure 26 shows this procedure.
First, input a start condition. Then transmit 9 clocks (dummy clock) of SCL. During this time, the master device sets
the SDA line to “H”. By this operation, the S-24C04C interrupts the acknowledgment output operation or data
output, so input a start condition
input the stop condition to the S-24C04C. The normal operation is then possible.
*1. After 9 clocks (dummy clock), if the SCL clock continues to being output without inputting a start condition, S-
Remark
_00_C
24C04C may go in the write operation when it receives a stop condition. To prevent this, input a start condition
after 9 clocks (dummy clock).
Regarding this reset procedure with dummy clock, it is recommended to perform at the system
initialization after applying the power supply voltage.
Condition
Start
1
*1
. When a start condition is input, the S-24C04C is reset. To make doubly sure,
Figure 26 Resetting S-24C04C
2
Dummy Clock
Seiko Instruments Inc.
8
9
Condition
Start
2-WIRE SERIAL E
Condition
Stop
S-24C04C
2
PROM
23

Related parts for s-24c04c