top221 Power Integrations, Inc., top221 Datasheet - Page 16

no-image

top221

Manufacturer Part Number
top221
Description
Three-terminal Off-line Pwm Switch
Manufacturer
Power Integrations, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
top221G
Manufacturer:
POWER
Quantity:
1 500
Part Number:
top221G
Quantity:
5 510
Part Number:
top221G
Manufacturer:
INFINEON
Quantity:
5 510
Part Number:
top221G
Manufacturer:
POWER
Quantity:
11 447
Part Number:
top221GN
Manufacturer:
PowerInt
Quantity:
250
Part Number:
top221GN
Manufacturer:
GF
Quantity:
6 227
Part Number:
top221GN
Manufacturer:
POWER
Quantity:
20 000
Part Number:
top221GN-TL
Manufacturer:
POWER
Quantity:
20 000
Company:
Part Number:
top221GN-TL
Quantity:
6 800
Company:
Part Number:
top221GN-TL
Quantity:
134
Part Number:
top221P
Manufacturer:
POWER
Quantity:
20 000
Part Number:
top221PN
Quantity:
1 984
Part Number:
top221PN
Manufacturer:
ST
0
Part Number:
top221PN
Manufacturer:
POWER
Quantity:
20 000
Company:
Part Number:
top221PN
Quantity:
3 000
The following precautions should be followed when testing
TOPSwitch by itself outside of a power supply. The schematic
shown in Figure 14 is suggested for laboratory testing of
TOPSwitch.
When the DRAIN supply is turned on, the part will be in the
Auto-restart mode. The CONTROL pin voltage will be
oscillating at a low frequency from 4.7 to 5.7 V and the DRAIN
is turned on every eighth cycle of the CONTROL pin oscillation.
If the CONTROL pin power supply is turned on while in this
Typical Performance Characteristics
16
TOP221-227
BENCH TEST PRECAUTIONS FOR EVALUATION OF ELECTRICAL CHARACTERISTICS
CURRENT LIMIT vs. TEMPERATURE
BREAKDOWN vs. TEMPERATURE
D
7/01
1.1
1.0
0.9
1.2
1.0
0.8
0.6
0.4
0.2
0
-50 -25
-50 -25
Junction Temperature ( C)
Junction Temperature ( C)
0
0
25
25
50
50
75 100 125 150
75 100 125 150
Auto-restart mode, there is only a 12.5% chance that the control
pin oscillation will be in the correct state (DRAIN active state)
so that the continuous DRAIN voltage waveform may be
observed. It is recommended that the V
turned on first and the DRAIN power supply second if continuous
drain voltage waveforms are to be observed. The 12.5% chance
of being in the correct state is due to the 8:1 counter. Temporarily
shorting the CONTROL pin to the SOURCE pin will reset
TOPSwitch, which then will come up in the correct state.
FREQUENCY vs. TEMPERATURE
1.6
1.2
0.8
0.4
2
0
1.2
1.0
0.8
0.6
0.4
0.2
0
0
I
-50 -25
C
V C = 5 V
vs. DRAIN VOLTAGE
Junction Temperature ( C)
20
DRAIN Voltage (V)
0
40
25
50
60
75 100 125 150
80
C
power supply be
100